+371 672 70580

Mon-Fri: 9:00 - 17:00 LV

Email:

DWYER PUB portable ultrasonic flowmeter kit

The Series PUB & PUF Portable Ultrasonic Flowmeter Kits utilize the transit-time difference for measuring flow rates in pipes non-invasively. They are compact and lightweight instruments incorporating the latest electronics and signal processing technologies, realizing high performance and easy operation. These devices are perfect for on-the-go flow monitoring, capable of 20 hours continuous operation with built-in, rechargeable battery. The PUB comes with a rugged carrying case with molded foam inserts while the PUF boasts an IP67 rated case to hold and protect all equipment conveniently. Their screens offer easy to read text with convenient backlight for visual comfort. The efficient layout of the function keys adds to these units’ easy to use programming. These series offer analog as well as a pulsed outputs.

			int(5597)
NULL
		

Made in USA. brand DWYER, model PUB

Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.

Retailprice from $8540,8

Available

Available

Founded in 1931, DWYER manufactures equipment for measurement, conversion and control – pressure, temperature, level, flow.

Advantages

Official distributor in Latvia

Time-tested American, European and Asian brands of control and measurent instruments

Advantages

Special price list for organisations

We offer a significant discount for trade organisations and manufacturing companies

Advantages

Worldwide shipping on request

We take care of all logistics and customs clearance. Fast delivery to Baltic countries

Advantages

After-sales service and support

Warranty service and repair, expert assistance in the operation of the instruments

Description of DWYER PUB

PRINCIPLES OF OPERATION
Two sensors are placed on the exterior of the pipe, and each transmits an ultrasonic pulse through the pipe and fluid to the other. The velocity of the liquid flowing through the pipes causes the pulse to accelerate or decelerate. The difference in the transit times of the two pulses is used to calculate the flow rate. The use of transit time allows the flowmeter to be unaffected by pressure or temperature changes.

Calibration Option available under Accessories.

PRODUCT APPLICATIONS

  • Treated Water
  • River Water
  • Potable Water
  • Demineralized Water
  • Glycol/water mix
  • Hydraulic System
  • Diesel Oil
  • Sea Water

FEATURES

Kit Includes:

  • Converter
  • Set of Transducers
  • Transducer Holders
  • Set Transducer Cables (6.56′ (2 m))
  • 4 to 20 mA Communication Cables
  • 12 VDC Power Supply
  • Ultrasonic Coupling Grease
  • Set of Chains
  • Ruled Guide Rail
  • Test Block
  • Carrying Case

Technical specifications of DWYER PUB

  • Service: Homogeneous liquids that do not contain air bubbles capable of ultrasonic wave propagation.
  • Inputs: Lemo connector cable from sensors.
  • Range: 0.33 to 65.62 ft/s (0.1 to 20 m/s).
  • Display: 240 x 64 pixel graphic display, high contrast black on white with backlight; Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5.2″ W x 1.5″ H.
  • Accuracy: ±0.5 to 2% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and pipe ID > 2.95″ (75 mm); ±3% of flow reading for flow rate > 0.66 ft/s (0.2 m/s) and pipe ID in range 0.512 to 2.95″ (13 to 75 mm); ±6% of flow reading for flow rate < 0.66 ft/s (0.2 m/s).
  • Power Requirements: 9 to 24 VDC, (1) 5-Cell NiMH battery, internal, factory replaceable (continuous operation time: 20 hours with back-light and output off) (recharging time: 6.5 hours, power adapter used).
  • Power Consumption: 10.5 W.
  • Power Adapter: 110/240 VAC adapter. UK, US, European adapters included.
  • Temperature Limits: -4 to 275°F (-20 to 135°C).
  • Outputs: Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 Ω max; Pulse: 1 opto-isolated MOSFET relay, 150 mA max, 500 pps max, 200 Hz max.
  • Enclosure Rating: Converter: IP54; Transducers: IP51.
  • Materials: Flame retardant injection molded ABS plastic.
  • Repeatability: ±0.5 % of measured value or ±0.066 ft/s (0.02 m/s).
  • Electrical Connections: Multi-pin Lemo plugs.
  • Turbidity: < 3% by volume of particulate content.
  • Permissible Air Content: < 3% by volume.
  • Response Time: < 500 ms.
  • Weight: Unit without accessories: 2.3 lb (1.06 kg); Unit with accessories in carrying case: 13.23 lb (6.0 kg).
  • Compliance: CE.

ADDITIONAL SPECIFICATIONS

  • Applicable Pipe Material: Carbon steel, SS, copper, UPVC/PVDF, concrete, galvanized steel, mild steel, glass, brass.
  • Applicable Pipe Lining: Rubber, glass, concrete, epoxy, steel, other*.
  • Pipe Wall Thickness: 0.04 to 3″ (1 to 75 mm).
  • Pipe Lining Thickness: < 1″ (< 25 mm).

How to buy DWYER PUB

Model Description Price
PUB-20 Portable ultrasonic flowmeter converter Type B, 2″ to 40″ (50.7 to 1016 mm) pipe diameter range.
$8,540.80
Load More Items

Accessories for DWYER PUB

Model Description Price
NISTCAL-FU NIST traceable calibration certificate for ultrasonic flowmeters. NOTE: EQUAL CERTS WILL BE CHARGED PER UNITS PURCHASED.
$405.00
Load More Items

User Guide and Instruction manual for DWYER PUB

You can request the necessary certificates, documentation, instructions and user guide for DWYER PUB using the special form.

You can buy DWYER PUB in Latvia at a price starting from8540,8 $ in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email . DWYER PUB price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.