Products not found
The Series AN2 Indicating Alarm Annunciator provides visible and audible alarms for up to eight inputs. The annunciator also has two SPDT relay outputs that can be used to initiate external alarms, buzzers, or paging devices. The Integral 24 VDC power supply can power most level, temperature, pressure, and flow switches. Audible alarm conditions can be acknowledged, reset, or silenced either via the front panel push buttons or the rear terminal block. The Series AN2 can be set to any common ISA sequences including First-Out.
Retail price from $662,4
The Model CPS Cable Pull Switch is designed to provide a switching system to isolate the power to the conveyor system or other similar process equipment in event of a shutdown condition. A steel wire is placed along the side of the conveyor and attached to the cable pull switch. When the cable is pulled at any point along the conveyor it will trip the cable pull switch causing the conveyor to shut down. To restart the conveyor the CPS must be manually reset. The CPS has a universal design for bi-directional activation and utilizes a highly visible red flag to indicate the switch status. The compact design makes it ideal for easy installation.м
Retail price from $361,2
The Series PMT2 Particulate Transmitter is designed to measure particulate emission levels from dust collector discharge. Using DC coupled electrostatic induction sensing technology, the transmitter monitors a pA current that is generated as particulate passes near the probe; a 4 to 20 mA signal will vary based on the particulate level. The PMT2 offers 6 sensitivity ranges allowing the user to choose the range that will best fit the application. The range and test selector switch can also be set to output a 4 mA or 20 mA signal to assist with set up or trouble shooting. Averaging time setting can be used to dampen the signal if desired.
Retail price from $2422,15
The Series SL-2000 Duct Smoke Detector is crucial for early detection of smoke and products of combustion present within HVAC ductwork. This series can be utilized in many different types of applications including commercial, industrial, and residential. The unit is designed to not only alarm when smoke is detected, but will also utilize relays to disable fans and blowers. The series comes complete with technician friendly “No-Tools Required” features to make installation and servicing simple and efficient.
Retail price from $278,65
The Series FPCA Flow Power Control Accessories include mounting kits, power converters, and power supplies for compatible flow meters. These accessories simplify installation by offering meter and wall mounting options. Furthermore, power input and supply are no longer an issue with the power converter and dual power supply. The WMK can be used to mount Series BAT, RTI, or PWD on Series PDWS. The MMK can be used to mount either Series BAT or RTI to a wall with the use of Series EFS2, IEFS, PDWS, IPFS, TBS, or FLMG. Model PWC1 can be used with Series PDW, EFS2, or IEFS to convert 115 VAC to 25 VDC. Model PWC2 can be used with Series EFS2, IEFS, PDWS, IPFS, and TBS to convert 115 VAC to 12/24 VDC and provide dual power output for use with Series BAT and RTI.
Retail price from $159,5
The Series A-IEF Remote Display can be installed almost anywhere near a Series IEF flow transmitter or Series IEFB thermal energy meter. Both the indicator display (A-IEF-IDSP-RM) and the full functional display (A-IEF-FDSP-RM) have a maximum display cable length of 100 ft (30 m) to permit easy viewing of flow readings. The full functional display allows for convenient adjustment of configuration settings and allows the user to save the IEF or IEFB configuration settings to a computer for printing.
Retail price from $762,3
The Series RTI2 Rate & Total Indicator is an indicator/transmitter that takes the pulse output signal from compatible flowmeters, displays flow rate and total, and provides output signals. It is compatible with the Series IEF and PFT.
Retail price from $1026,7
Model TR-7 Safe-T-Ground provides continuous monitoring of a truck’s ground connection throughout loading operations. Static electricity is often brought in by tank trucks entering the loading area. The Safe-T-Ground Model TR-7 instantly stops loading operations if a tank truck loses its ground.
To safeguard loading operations, the Safe-T-Ground circuit can be wired into your pump control – and to an audible alarm or signal light.
Retail price from $1824,15
Model TAC-L Portable Digital Tachometer measures rotational speed either by contacting a rotatable head to the shaft of the object, or using photo sensor to detect the reflections from the laser. The laser target can record from a distance of up to 20 inches and gives a more accurate measurement than LED targeting. Model TAC-L includes a large LCD with a backlight for use in dark areas. This tachometer is made of a strong, lightweight ABS plastic housing, which is designed to comfortably fit in the hand of the user. Supplied with this model are 3 contact rotational heads, a contact surface wheel, and a protective carrying case.
Retail price from $114,55
The Model UTG Ultrasonic Thickness Gage measures the thickness of a variety of materials. The UTG works on a variety of parallel surface material ranging from 0.05 to 7.9″ (1.2 to 200 mm).
Retail price from $466,45
Retail price from $124
TSI Flow Calibrators are essential accessories for condensation particle counters and filter testers.
price by request
Cleans, dries, and regulates compressed air for aerosol generation and other applications.
price by request
Wireless Airflow, Temperature, & Humidity Adaptor
Retail price from $327,49
Wireless Pipe Clamp Temperature Probes x1 (2)
Retail price from $151,25
Outdoor air temperature measurements for target superheat calculation
Retail price from $130,45
1(2) Wireless Hygrometer Probes
Retail price from $151,54
Wireless Pipe Clamp Temperature Probe
Retail price from $275,4
TSI’s FMS system is an advanced, reliable, and user-friendly monitoring software suite that features a truly distributed architecture. High availability databases and hot standby system failover functionality assures compliance and peace of mind. Standard inputs include: airborne particle counters (multiple manufacturers supported), temperature/humidity, differential pressures, air velocity and digital inputs. Any device that has a linear analog output can be integrated into FMS including:
price by request
The Flow Splitter directs an aerosol sample to as many as four destinations at once.
price by request