Products not found
Miniature sensor, with flexible lead wire in armour, suitable for temperature measurement of movable elements, e.g. press moulds, injection moulds etc. It can be applied to measurement of liquids in small tanks and pipelines where atmospheric pressure occurs.
- insulated hot junction SO
- bayonet mount enables quick mounting and immersion length adjustment (good contact with the seat)
- nickel-plated brass, atmospheric pressure
price by request
Sensor suitable for temperature measurement of motor windings. Sensor construction enables quick and easy installation.
- flexible laminate with heat shrink jacket
- Cu wire resistance ~0,14 Ω/m = ~0,36°C
price by request
Temperature sensor suitable for measurement of outside temperature, both in places exposed to sun and not, mainly in air-conditioning and automation systems of district heating substations. Resistor is placed in a plastic housing. Optionally, sensor can be equipped with transmitter converting measured value to 4÷20mA current.
- closed-end sheath
- humidity max. 85% RH
- housing: material polycarbonate, IP67
- material: stainless steel 1.4541
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. Tight connection of the sensor and thermowell prevents leakage of installation and enables adjustment to the thickness of insulation layer. This sensor has a spring-loaded replaceable measuring insert. Adequate for various applications, mainly on ships and vessels.
- process connection with G1/2 or M20x1,5 thread
- connection head type BA IP55, – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ext IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541, 1.4841, 1.4762
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68,cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price by request
Temperature sensor suitable for temperature measurement of liquid and gaseous media. Built-in LED display enables local temperature reading.
- Temperatura range -200÷550ºC RTD
- sensing element: Pt100/Pt500/Pt1000 resistor
- process connection with G1/2 or M20x1,5 thread
- connection head type XDI-80, IP65 – 20÷70ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
price by request
Sensor suitable for temperature measurement of machinery and device parts. Characteristic for this sensor is that sensing element is placed directly in process connection.
- sheath with thread
- fiberglass insulation, metallic overbraid
- material: stainless steel 1.4541
price by request
Sensor suitable for temperature measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of resistor placed in the thin-walled acid-resistant sheath with welded process connection and plug installed on the sheath. It is equipped with additional straight or angled connector for joining lead wire with outer devices
- connector operating temperature: (-40 ÷ 100) °C
- plug GDM + socket GSP (IP65)
- material: stainless steel 1.4541
- sheath constricted ø6/ø4 mm
price by request
Temperature sensor suitable for measurement of liquids, semi-liquid masses or loose materials. Temperature measurement can be carried out in a temporary or permanent way. This sensor has sheath with threaded connector.
- sensing element: Pt100/Pt500/Pt1000
- process connection with G1/2, G3/8 other
- connection head type MA, IP54, -40÷100ºC
- sheath material: acid-resistant steel 1.4541
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- process connection with G1/2 or M20x1,5, 1/2NPT thread
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541, flange PN16, DN20. DN25
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price by request
Temperature sensors suitable for temperature measurement of liquid and gaseous media. Sensing element is placed directly in the thermowell.
- Temperatura range -200÷150ºC RTD
- sensing element: Pt100/Pt500/Pt1000 resistor
- process connection with G1/2 or M20x1,5 thread
- connection head type BA IP55, – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
price by request
Sensor suitable for temperature measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This Sensor consists of sensing element placed in the thin-walled acid-resistant sheath with connector and flexible lead wire.
- stranded Cu wire: 2×0,22 mm2
- hot junction: insulated SO, grounded SP
- material: stainless steel 1.4541
price by request
Sensor suitable for temperature measurement in district heating substations. Applicable also for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of resistor placed in the thin-walled acid-resistant sheath connected to flexible lead wire.
- operating temperature -30÷85°C
- screwed plug M12-4 pin – IP67
- material: stainless steel 1.4541
price by request
Temperature sensor suitable for measurement of liquid and gaseous media, mainly in systems for energy consumption billing.
- sensor pair Pt100 and Pt500 with Central Offi ce of Measures (GUM) approval type PTL05304
- stranded Cu wire 2×0,25 mm2 with double silicone insulation
- outer thermowell for sensor mounting in pipelines
- sheath material:brass
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541 or 1.7335
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price by request
Temperature sensors suitable for temperature measurement of liquid and gaseous media. Sensing element is placed directly in the thermowell.
- Temperatura range -200÷600ºC RTD
- sensing element: Pt100/Pt500/Pt1000 resistor
- process connection with G1/2 or M20x1,5 thread
- connection head type BA IP55, – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
price by request
Sensor suitable for temperature measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. Sensor consists of sensing element placed in the thin-walled acid-resistant sheath with connector and flexible lead wire.
- stranded Cu wire: 2×0,22 mm2
- hot junction: insulated SO, grounded SP
- material: stainless steel 1.4541
price by request
Sensor suitable for temperature measurement in district heating substations. Applicable also for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of resistor placed in the thin-walled acid-resistant sheath with welded process connection and plug installed on the sheath. It is equipped with additional straight or angled connector for joining lead wire with outer devices.
- connector with bayonet mount
- threaded connector, welded to sheath
- material: stainless steel 1.4541
price by request
Temperature sensor suitable for measurement of liquid and gaseous media, mainly in systems for energy consumption billing.
- sensing element: Pt100/Pt500/Pt1000 resistor or J, K, N, T thermocouple
- process connection with G1/2 or M20x1,5 thread
- connection head type MA IP54, – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541 flange PN16, DN20, DN25
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price by request
Temperature sensor applied in industrial pipelines, pressure and other tanks for temperature measurement of liquids and gases. Sensing element is placed directly in the thermowell.
- Temperatura range -200÷150ºC RTD
- sensing element: Pt100/Pt500/Pt1000 resistor
- process connection with G1/2 or M20x1,5 thread
- connection head type MA IP54 – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
price by request