+371 672 70580

Mon-Fri: 9:00 - 17:00 LV

Email:

LIMATHERM TOPT-EXD RTD

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66

  • process connection with G1/2 or M20x1,5, 1/2NPT thread
  • aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
  • aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
  • stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
  • sheath material: acid-resistant steel 1.4541, flange PN16, DN20. DN25
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
  • Exd acc. to ATEX
			int(8800)
NULL
		

Made in Poland. brand LIMATHERM, model TOPT-EXD

Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.

price by request

Available

Available

Advantages

Official distributor in Latvia

Time-tested American, European and Asian brands of control and measurent instruments

Advantages

Special price list for organisations

We offer a significant discount for trade organisations and manufacturing companies

Advantages

Worldwide shipping on request

We take care of all logistics and customs clearance. Fast delivery to Baltic countries

Advantages

After-sales service and support

Warranty service and repair, expert assistance in the operation of the instruments

Technical specifications of TOPT-EXD

Measuring range / sensing element:

  • (-200 ÷ 550) ºC / Pt100/ class B

Measuring insert:

  • 3-, 4-wire connection (for Pt100)
  • 3-wire connection (for 2xPt100)
  • insert length: L+164mm

Thermowell:

  • material: steel 1.4541; flange PN16, DN20 or DN25* with rebate B1
  • diameter d [mm]: ø11, ø12, ø14
  • length L [mm]: 50÷2000

Connection head:

  • aluminium XD-AD (AS1 – one cable gland, AS2 – two cable glands),
  • with display XD-ADwin (AS3 – one cable gland, AS4 – two cable glands),
  • stainless steel XD-SD (NS1 – one cable gland, NS2 – two cable glands),
  • cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)

Construction version:

  • Exd acc. to ATEX
  • WE Type-Examination Certificate: KDB 08ATEX135
    I M2 Ex d I; (only with connection head NS1, NS2)
    II 2 GD Ex d IIC T6; Ex t IIIC T85 °C IP66

Options:

  • Pt500, Pt1000, T, N
  • other threads (inch and metric) acc. to requirements
  • Pt100: class A (-50 ÷ 400) ºC, class AA (0 ÷ 150) ºC; TC: class 1

Additional accessories:

  • temperature transmitters – p. 225÷241
  • local display LPI-02 (connection head AS3 or AS4) – p. 221
flange D2 [mm] D0 [mm] D1 [mm]
DN20 ø105 ø75 ø58
DN25 ø115 ø85 ø68

Response time T05/T09

Sensor type ø9 ø11
Pt ≤33/≤95 ≤40/≤120

Resistors tolerance acc. to PN-EN 60751

Class Wire wound resistor
Range [°C] Tolerance [°C]
AA (-50÷250) ±(0,1+0,0017∙|t|)
A (-100÷450) ±(0,15+0,002∙|t|)
B (-196÷600) ±(0,3+0,005∙|t|)

How to buy TOPT-EXD

Ordering example:  TOPT-Exd–NS1–600/11–DN20PN16B1–1A–3–a

User Guide and Instruction manual for LIMATHERM TOPT-EXD

You can request the necessary certificates, documentation, instructions and user guide for LIMATHERM TOPT-EXD using the special form.

You can buy LIMATHERM TOPT-EXD in Latvia at a favourable price in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email . LIMATHERM TOPT-EXD price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.