Flow element, also known as differential pressure flow meter, consists of a primary detection piece (flow element) and a secondary device (differential pressure transmitter and flow indicator). Flow element is the most stable and reliable of all flow meters, which has a history of more than 100 years. Its wide applicability, high reliability and accurate accuracy make it widely used in the measurement of gas, liquid and vapor.
Made in China. brand DDTOP, model LG Venturi
Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.
price by request
Available
Official distributor in Latvia
Time-tested American, European and Asian brands of control and measurent instruments
Special price list for organisations
We offer a significant discount for trade organisations and manufacturing companies
Worldwide shipping on request
We take care of all logistics and customs clearance. Fast delivery to Baltic countries
After-sales service and support
Warranty service and repair, expert assistance in the operation of the instruments
LG type venturi standard flow element has a long history and it is a widely used flow measuring instrument, with high accuracy, stable performance, low pressure loss (generally between 5% to 20% of the differential pressure value), easy to maintain, especially in the energy-saving work condition, it has the advantages of accurate measurement and reduced energy consumption, and has broad prospects in use.
Operating Principle
In the pipeline filled with single-phase continuous fluid, install a flow element (such as a venturi). When the fluid passes through the orifice of the flow element, the vapor forms a local contraction, the flow velocity increases, the kinetic energy increases, and the static pressure decreases.There is a static pressure difference between the front and back of the flow element, that is, ΔP = P1-P2. If the area of the orifice is F, the mass flow of the fluid is qm, the volume flow is qv, and the density is ρ, according to the principle of flow continuity and Bernoulli equation can derive the relationship between pressure difference and fluid flow:
In the formula, α is the flow coefficient. It can be seen from the above relationship that if the orifice area and fluid density are constant, the flow rate is proportional to the square root of the pressure difference, that is, as long as the pressure difference is measured, the flow rate can be calculated. The flow element measures the fluid flow rate based on this principle
Features
1.Structure is simple, easy to install, reliable to work, accuracy can meet the needs of engineering survey.
2.It has pure mechanical structure, according to the site high temperature and high pressure conditions to select appropriate structure and material. The highest pressure is 42 MPa and the highest temperature is 500℃.
3.Flow element has a long history of use, it has rich and reliable experimental data. Design and processing has been standardized. Standard orifice plate is no need to carry out the real flow calibration and maintenance.
Applications
DN300~DN1200(crude welded shrinkage section of iron plate)
0.4≤β≤0.7(crude welded shrinkage section of iron plate)
1. Model
Table 1 Flow Element Code and Meaning
Code | Meaning | Caliber |
J | Classic Venturi Tube Through Machining Shrinkage Section | DN50-DN250 |
H | Crude Welded Shrinkage Section Of Iron Plate | More than DN250 |
Table 2 Tap Method and Meaning
Code | Meaning |
T | Tap Equalizing Ring |
Z | Drilling Tap |
Table 3 Nominal Diameter Code and Meaning
Code | 01 | 016 | 02 | 026 | 03 | 04 | 05 | 06 | 08 | 10 | ||
DN | mm | 10 | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | |
in | 1/2 | 3/4 | 1 | 1-1/4 | 1-1/2 | 2 | 2-1/2 | 3 | 4 | |||
Code | 12 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 60 | ||
DN | mm | 125 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | 600 | |
in | 5 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 24 | ||
Code | 70 | 80 | 90 | 100 | 105 | 110 | 115 | 120 | 125 | 130 | ||
DN | mm | 700 | 800 | 900 | 1000 | 1050 | 1100 | 1150 | 1200 | 1250 | 1300 | |
in | 28 | 32 | 36 | 40 | 42 | 44 | 46 | 48 | 50 | 52 |
Table 4 Nominal Pressure Code and Meaning
Code | 01 | 02 | 03 | 04 | 05 | 06 | 10 | 11 | 15 | 16 | ||
PN | MPa | 1.6 | 2.0 | 2.5 | 4.0 | 5.0 | 6.3 | 10.0 | 11.0 | 15.0 | 16.0 | |
Class | 150 | 300 | 600 | 900 | ||||||||
Code | 26 | 42 | ||||||||||
PN | MPa | 26.0 | 42.0 | |||||||||
Class | 1500 | 2500 |
Table 5 Straight Pipe Section Code and Meaning
Code | A | B | C | D | E | F | |
Unit | Flow Element | Flow Element, Mounting Flange | Flow Element,
Mounting Flange, Upstream and downstream straight pipe section |
Flow Element,
Mounting Flange, Upstream and downstream straight pipe section, Upstream and downstream connection flange |
Flow Element,
Mounting Flange, Upstream and downstream straight pipe section, Upstream connection flange |
Flow Element,
Mounting Flange, Upstream and downstream straight pipe section, Downstream connection flange |
Welding Structure |
2.1 Flow Element Executive Standard
Code | Meaning | Standard Code |
J | Classic Venturi Tube Through Machining Shrinkage Section | GB/T2624—2006(ISO5167—1—2003) |
H | Crude Welded Shrinkage Section Of Iron Plate | GB/T2624—2006(ISO5167—1—2003) |
For example, DN50 CL300 flange connection tap equalizing ring venturi tube model is LGJT-0505A.
2.2 Flange and Gasket Executive Standard
Flange and gasket standards can be selected from HG/T20592~20614-09 (European system) or HG/T20615~20635-09 (American system) or other standards
You can request the necessary certificates, documentation, instructions and user guide for DDTOP LG Venturi using the special form.
You can buy DDTOP LG Venturi in Latvia at a favourable price in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email olil@olil.lv. DDTOP LG Venturi price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.
See also: Acid flow meters, Chemical flow meters, Digital flow meters, Explosion proof flow meters, Flanged flow meters, Flow meters, Flow meters for large pipes, Fuel & oil flow meters, Gas & air flow meters, High pressure flow meters, Hydrogen flow meters, Liquid & water flow meters, Mass flow meters, Nitrogen gas flow meters, Oxygen flow meters, Smart flow meters, Stainless steel flow meters, Steam flow meters, Venturi flow meters