Temperature sensor suitable for measurement of ambient temperature, mainly in industrial space like warehouses, production halls, etc. as well as under roofs and open spaces. It has an aesthetic housing made of plastic adequate for wall mounting and perforated sheath made of anodized aluminium. Optionally, sensor can be equipped with transmitter converting measured value to 4÷20mA current.
- perforated sheath
- humidity max. 85% RH
- housing: material polycarbonate, IP67
- material: stainless steel 1.4541
price by request
Temperature sensor suitable for pipelines, pressure tanks and other devices used in food and pharmaceutical industry. This stainless steel sensor has National Institute of Hygiene (PZH) attestation.
- process connection with M10x1 or M20x1,5 thread
- connection head type MBEG – material: stainless steel 1.4541, IP65 -40÷100°C
- sheath material: acid-resistant steel 1.4541
- national Institute of Hygiene (PZH) attestation
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: boilert steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price by request
Temperature sensor suitable for measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of sensing element placed in the thin-walled acid-resistant sheath with connector and flexible lead wire. Temperature sensor has ATEX approval for application in hazardous area: II 1/2G Ex ia IIC T6 II 1/2D
- welded threaded connector
- thermocouple sensor with insulated hot junction
- sheath material:stainless steel 1.4541
- Exi acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- process connection with G1/2 or M20x1,5, 1/2NPT thread
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541, 1.4571, 2.4816
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price by request
Sensor suitable for temperature measurements, primarily in industrial pressure tanks, in all these places where mounting of a threaded process connection would be problematic. The temperature sensor design (replaceable measuring insert) is suitable for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert guarantees an excellent connection with the bottom of the sensor thermowell.
- Temperatura range 0÷540ºC TC
- sensing element: K thermocouple
- process connection with G1/2 or M20x1,5 thread
- connection head type BA IP55, – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
- measuring insert: pipe or mineral insulated version
price by request
This sensor is used for temperature measurement of liquid and gaseous media. The temperature sensor design (replaceable measuring insert) is suitable for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the the bottom of the sensor thermowell.
- Temperatura range -40÷150ºC TC
- process connection with G1/2 or M20x1,5 thread
- connection head type BA IP55, – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
- measuring insert: pipe or mineral insulated version
price by request
Mineral insulated metal sheathed insert is used as a replaceable element of temperature sensors. Insert design enables its installation in the connection head and pressing insert tip to the bottom of the sensor thermowell.
- Temperatura range -200÷550ºC RTD
- sensing element: Pt100/Pt500/Pt1000 resistor
- sheath material: acid-resistant steel 1.4541, 1.4541, 2.4816
price by request
Temperature sensors suitable for temperature measurement of liquid and gaseous media. Sensing element is placed directly in the thermowell.
- Temperatura range -40÷150ºC TC
- sensing element: J thermocouple
- process connection with G1/2 or M20x1,5 thread
- connection head type BA IP55, – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
price by request
Temperature sensor applied in industrial pipelines, pressure tanks and different industrial devices for temperature measurement of liquids and gases. Sensing element is placed directly in the sheath.
- Temperatura range -40÷700ºC TC
- sensing element: K thermocouple
- connection head type BA IP55, – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
price by request
Temperature sensor suitable for measurement primarily in heat-treating furnaces, boiler houses, etc. This sensor has ceramic protection tube.
- Temperatura range: 600÷1700ºC B
- ceramic tube: mullite 610 or corundum 799
- connection head type AA IP53, – 40÷100ºC
- sheath material: acid-resistant steel 1.4841, and ceramic
- temperature transmitter can be mounted in a connection head
price by request
Temperature sensor designed to measuring motor windings. Its construction allows for quick and simple assembly.
price by request
Sensor suitable for temperature measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. Sensor consists of sensing element placed in the thin-walled acid-resistant sheath with connector and flexible lead wire.
- stranded Cu wire: 2×0,22 mm2
- hot junction: insulated SO, grounded SP
- material: stainless steel 1.4541
price by request
Sensor applied for temperature measurement of movable and exposed to vibrationparts of machines and devices.
- mineral insulated thermocouple (J), material: stainless steel 1.4541
- connector and tip material: stainless steel 1.4541
price by request
Temperature sensor suitable for surface measurement. Hot junction has bigger surface of heat reception because of the connected copper plate or eyelet. This improves sensor contact with the surface.
- cable tip with eyelet, clamped hot junction, surface mounting with M4 or M5 screw
- square or round plate, brazed hot junction
- thermocouple stranded wire: 2×0,22 mm2
price by request
Sensor suitable for temperature measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of resistor placed in the thin-walled acid-resistant sheath with welded process connection and plug installed on the sheath. It is equipped with additional straight or angled connector for joining lead wire with outer devices
- connector operating temperature: (-40 ÷ 100) °C
- plug GDM + socket GSP (IP65)
- material: stainless steel 1.4541
- sheath constricted ø6/ø4 mm
price by request
Mineral insulated sensor with strengthened sheath suitable for measurement of liquids, semifluid masses or loose materials with high density or flow in conditions of great vibrations.
- other lead wire insulation types: tefl on, armour, fi berglass
- mineral insulated thermocouple ø4,5 mm, with sleeve and nut M14x1,5 for sensor mounting
- materia: stainless steel 1.4541 and INCONEL
price by request
Temperature sensor suitable for measurement of living quarters and office space, mainly in ventilation and air-conditioning systems. Flexible housing made of plastic is adequate for wall mounting. Optionally, sensor can be equipped with transmitter converting measured value to 4÷20mA current.
- without – unsheathed measuring resistor inside perforated housing
- humidity max. 85% RH
- material: ABS, IP-20
- mounting holes span 48 mm
price by request
Temperature sensor suitable for pipelines, pressure tanks and other devices used in food and pharmaceutical industry. This stainless steel sensor has National Institute of Hygiene (PZH) attestation.
- process connection with M10x1 or M20x1,5 thread
- connection head type MBEG – material: stainless steel 1.4541, IP65 -40÷100°C
- sheath material: acid-resistant steel 1.4541
- national Institute of Hygiene (PZH) attestation
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: boilert steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price by request
Temperature sensor suitable for measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of sensing element placed in the thin-walled acid-resistant sheath with connector and flexible lead wire. Temperature sensor has ATEX approval for application in hazardous area: II 1/2G Ex ia IIC T6 II 1/2D
- welded threaded connector
- thermocouple sensor with insulated hot junction
- sheath material:stainless steel 1.4541
- Exi acc. to ATEX
price by request