- radiator enhancing surface of heat reception with band clamp for mounting on a pipeline DN 15÷200 mm
- insulated hot junction SO
- material: brass
Products not found
Temperature sensor suitable for measurement of living quarters and office space, mainly in ventilation and air-conditioning systems. Flexible housing made of plastic is adequate for wall mounting. Optionally, sensor can be equipped with transmitter converting measured value to 4÷20mA current.
- without – unsheathed measuring resistor inside perforated housing
- humidity max. 85% RH
- material: ABS, IP-20
- mounting holes span 48 mm
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- process connection with G1/2 or M20x1,5, 1/2NPT thread
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541, flange PN16, DN20. DN25
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price by request
Temperature sensor suitable for measurement of movable or replaceableparts of machines and devices, e.g. bearings or injection moulds. Equipped with bayonet fitting that enables quick and easy installation in the measured element. Furthermore, the sensor has a spring that protects the flexible cable. The cap of a bayonet fitting can be easily moved across the spring enabling the adjustment of sensor immersion length.
- Temperatura range -50÷400ºC Pt100
- connector with bayonet mount
- bayonet fitting with connector– nickel-plated brass
- material: stainless steel 1.4541
price by request
Temperature sensor suitable for measurement of pipes and shafts. Rigid sheath is joined to radiator enhancing the area of heat reception. Sensor has a band clamp that enables permanent radiator installation on pipe or shaft.
price by request
Temperature sensor suitable for measurement of outside temperature, both in places exposed to sun and not, mainly in air-conditioning and automation systems of district heating substations. Resistor is placed in a plastic housing. Optionally, sensor can be equipped with transmitter converting measured value to 4÷20mA current.
- closed-end sheath
- humidity max. 85% RH
- housing: material polycarbonate, IP67
- material: stainless steel 1.4541
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541 or 1.7335
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price by request