+371 672 70580

Mon-Fri: 9:00 - 17:00 LV

Email:

Advantages

Official distributor in Latvia

Time-tested American, European and Asian brands of control and measurent instruments

Advantages

Special price list for organisations

We offer a significant discount for trade organisations and manufacturing companies

Advantages

Worldwide shipping on request

We take care of all logistics and customs clearance. Fast delivery to Baltic countries

Advantages

After-sales service and support

Warranty service and repair, expert assistance in the operation of the instruments

Instrument filter

Instrument filter

Intrinsically Safe Temperature Sensors Exia

Our company offers you to buy intrinsically safe temperature sensor Exia at excellent price. Fast shipping to Latvia, Estonia and Lithuania. Worldwide delivery to Europe, Asia, Africa, North and South America available on request. If you need a trusted supplier – Leave a request on the website and our specialists will send you a price list within 1-2 days.

Products not found

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: II 2G Ex ia IIB T6 cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • holding tube
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • ceramic protection tube material: corundum 799
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: II 2G Ex ia IIB T6 cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • holding tube
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • ceramic protection tube material: corundum 799
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541, 1.4841 or 1.4762
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: II 2G Ex ia IIB T6 cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • holding tube
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • ceramic protection tube material: corundum 799
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541, 1.4841 or 1.4762
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of pipes and shafts. Rigid (pipe) sheath is joined to radiator enhancing the area of heat reception. Sensor has a band clamp that enables permanent radiator installation on pipe or shaft. Temperature sensor has ATEX approval for application in hazardous area: II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C

  • radiator enhancing surface of heat reception
  • band clamp for mounting on a pipeline
  • sheath material: brass

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541, 1.4841 or 1.4762
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of sensing element placed in the thin-walled acid-resistant sheath with connector and flexible lead wire. Temperature sensor has ATEX approval for application in hazardous area: II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C

  • standard (pipe) execution
  • mineral insulated execution with sleeve
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of sensing element placed in the thin-walled acid-resistant sheath with connector and flexible lead wire. Temperature sensor has ATEX approval for application in hazardous area: II 1/2G Ex ia IIC T6 II 1/2D

  • welded threaded connector
  • thermocouple sensor with insulated hot junction
  • sheath material:stainless steel 1.4541
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of sensing element placed in the thin-walled acid-resistant sheath with connector and flexible lead wire. Temperature sensor has ATEX approval for application in hazardous area: II 1/2G Ex ia IIC T6 II 1/2D

  • welded threaded connector
  • thermocouple sensor with insulated hot junction
  • sheath material:stainless steel 1.4541
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 2G Ex ia IIC T6 II 2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of sensing element placed in the thin-walled acid-resistant sheath with connector and flexible lead wire. Temperature sensor has ATEX approval for application in hazardous area: II 1/2G Ex ia IIC T6 II 1/2D

  • welded threaded connector
  • thermocouple sensor with insulated hot junction
  • sheath material:stainless steel 1.4541
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: boilert steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of sensing element placed in the thin-walled acid-resistant sheath with connector and flexible lead wire. Temperature sensor has ATEX approval for application in hazardous area: II 1

  • movable threaded connector or nut
  • thermocouple sensor with insulated hot junction
  • sheath material: stainless steel 1.4541

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: boilert steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available

Temperature sensor suitable for measurement in district heating substations. Applicable for temperature measurement of liquid and gaseous media in high pressure conditions. This sensor consists of sensing element placed in the thin-walled acid-resistant sheath with connector and flexible lead wire. Temperature sensor has ATEX approval for application in hazardous area: II 1

  • movable threaded connector or nut
  • thermocouple sensor with insulated hot junction
  • sheath material: stainless steel 1.4541

price by request

Read more
Available

Available

Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)

  • process connection with G1/2 or M20x1,5 thread
  • connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
    XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65
  • sheath material: acid-resistant steel 1.4541
  • cable gland ATEX II GD IP65 (for cable 5÷10 mm)
  • Exi acc. to ATEX

price by request

Read more
Available

Available