TRIO.BAS MONO FILTER Portable Microbial Active Air Sampler

Portable Microbial Active Air Sampler with a single aspirating chamber, designed for Petri dishes. Equipped with a HEPA filter on the aspirating head, Bluetooth, and USB cable for data transfer. Provides an air flow of 100 litres per minute.

			int(27895)
NULL
		

Made in Italy. brand TRIO.BAS, model MONO FILTER

Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.

Retail price from 4 770 €

Available

Available

Advantages

Official distributor in Latvia

Time-tested American, European and Asian brands of control and measurent instruments

Advantages

Special price list for organisations

We offer a significant discount for trade organisations and manufacturing companies

Advantages

Worldwide shipping on request

We take care of all logistics and customs clearance. Fast delivery to Baltic countries

Advantages

After-sales service and support

Warranty service and repair, expert assistance in the operation of the instruments

Description of TRIO.BAS MONO FILTER

The sampler features a light weight and ergonomic balanced design to facilitate handling with or without gloved hands. The model is equipped with a HEPA filter installed at the outlet of the aspirating head. This solution prevents the potential transfer of particles from the interior of the instrument when moving between zones with different levels of microbial contamination (e.g., from Grade C to Grade A). The HEPA filter is located externally, which simplifies its replacement. The electric motor of TRIO.BAS microbial air samplers does not generate particles after the cleaning procedure.

Features:

  • The barcode module with a Bluetooth scanner automatically records the operator, place and plates used for sampling. The data collected by the barcode reader is transmitted directly to the instrument. This solution is useful for those who already use culture plates with barcode or 2-D barcode (QR Quick Response Code). The data collected is transferred via Bluetooth from the air sampler to a PC or laptop. PC or laptop requires dedicated software installed.
  • The data are transferred via Bluetooth between the air sampler and a smartphone or tablet (Android), and then to a PC or laptop.
  • The data may be transferred via cable, too. This is helpful for all companies that, due to internal policy, are not allowed to use wireless transfer.
  • It is possible to work either in manual or automatic mode.
  • Manual and automatic passwords (cascade access levels)
  • LED on the left side of visual display shows sampling status according to different numbers of flashes (Waiting delay time, Sampling in progress, Sampling pause)
  • Automatic next calibration reminder
  • Delayed, remote, simultaneous start or interval sampling
  • Data integrity CFR 21 Part 11 and GAMP5 compliant
  • The sampler is IP65 certified for protection from dust and water.
  • The battery is recharged by a power cable connected directly to the air sampler.
  • The use of sterile Daily Shift aspirating heads reduces the risk of contamination.
  • Production in ISO 9001 certified premises

Applications: Pharmaceuticals, cleanrooms, and biotech industries.

Technical specifications of TRIO.BAS MONO FILTER

Body Type Shockproof technopolymer body with antibacterial surface properties
Standards ISO 14698-1, EN 17141, GMP, GLP, and GAMP5
Aspirating Head Type Stainless steel with quick bayonet closure, identification number, and stainless steel cover to prevent contamination
Air Flow Rate: 100 L/min
Selected Air Volume: From 30 to 2,000 liters and 17 preset programs
Aspirating Chamber: Suitable for 55 mm Contact plates or 90 mm Petri dishes
Auto-calibration: Electronic power/flow control in real time
Power Supply System: The instrument can be continuously charged via AC power source 110/240 Volt 50/60 Hz or by rechargeable batteries (inserted inside the air sampler)
Filter: HEPA
Battery Cycle Autonomy: 30,000 liters
Language: English, French, German, Spanish, Italian
Operative Aspirating Cycles: Manual and Automatic
Data Storage: Memory storage of up to 1,000 samplings
Configuration: 50 users and 50 places
Start Modes: Delayed, remote, simultaneous start, interval sampling
Body Protection: IP65 (dust and water protection)
Data Transfer: Bluetooth or cable
Marking: CE
Dimensions: 33×16×15 (H) cm
Weight: 1,440 g
Production: ISO 9001 certified premises
Expand Table

Accessories for TRIO.BAS MONO FILTER

Photo Model Description
520 Ultra-lightweight and compact portable Bluetooth printer with high printing autonomy. Equipped with a paper end sensor and supports printing of the most common barcodes.
421 TRIO printer paper roll, 57 mm (10 pcs/pack)
423 Thermal paper rolls, size 57 mm (10 pcs/pack). Indelible thermal paper for TRIO printers.
294 Bluetooth barcode scanner — dimensions 60x35x15 mm (H), weight 45 g. 1D/2D barcode scanner module (optional, for use in GMP/GLP)
291 Barcode labels for identifying sampling locations, size 85×55 mm (10 pcs/pack)
340 Daily Shift sterile replacement suction head for contact cups (55 mm) — in double sterile packaging (20 pcs/pack), minimum order: 4 packs
341 Daily Shift sterile replaceable aspiration head for Petri dishes (90 mm) — in double sterile packaging (20 pcs/pack), minimum order: 4 packs
395 These Carrying cases have very performing characteristics. They ensure the safe transport of the instruments.
381 Sterile bags, ideal for safe storage and transport of Petri dishes, contact dishes, swabs, or other items outside the clean room
175 Convenient GLP stainless steel cup holder for clean rooms with a guide for stacking, storing, and transporting culture cups (Petri or contact cups). Used to maintain distance inside the incubator in accordance with GLP.
180 IN-REST holder. Temporary stand for cups with culture medium and/or their lids, as well as the device’s aspiration heads.
371 Compact MINI mobile cart with multifunctional holder for clean rooms, convenient for installing a sampler at medium height. It has two shelves, is stable, and easy to use.
372 MAXI cart with multifunctional holder — stainless steel cart on wheels, complete with table holder and vertical pull-out support with hook. Dimensions: 25x35x70 cm (H) (height adjustment range: 100 to 210 cm). Designed for MONO, DUO, and TRIO models.
387 The floor tripod is designed for convenient and safe sampling at medium and high heights. Lightweight and height-adjustable up to 366 cm, it ensures a stable setup of the air sampler and facilitates operator activity with quick fixation without screwing. Ideal for mobile use in areas with hard-to-reach sampling points.
523 Stainless steel floor stand. Adjustable height from 150 to 200 cm ensures convenient sampling at medium height. Supports direct attachment of the sampler or installation of a holder-stand (optional). A ball joint allows you to fix the device and adjust its position.
521 Vertical stainless steel hook with handle — for mounting on a table, trolley, or floor stand. Compatible with MINI, MONO, DUO, and TRIO models. Dimensions: 12x15x25 cm (H*).
530 Wall/desk mount. Can be placed on any work surface or mounted on a wall to hold the air sampler in the direction of the air flow coming out of the supply vent.
376 MAXI stand holder. Made of durable high-density technopolymer. Allows for vertical installation of the sampler with one hand. Compatible with any work surface, tripods, and the MINI trolley. Allows for easy charging of the device and replacement of cups without removing them from the mount.
501 IQ (installation qualification) and OQ (operational qualification) documents for: MONO
506 PQ (performance qualification) documents for: MONO
Expand Table

Prices for TRIO.BAS MONO FILTER

Model Description Price, €
170K Complete set: TRIO.BAS MONO FILTER Air sampler 171, 1x s/s ASPI HEAD Contact plate 330, 1x COVER HEAD s/s to protect ASPI HEAD 465, 1x ROBUSTUS STANDARD carrying case 395 5070
171K Complete set: TRIO.BAS MONO FILTER Air sampler 170, 1x s/s ASPI HEAD Petri plate 331, 1x COVER HEAD s/s to protect ASPI HEAD 465, 1x ROBUSTUS STANDARD carrying case 395 5070
170 TRIO.BAS MONO BLUETOOTH FILTER air sampler (100 lts/min) Petri 90 plate with battery charger 100/240VCA 18VDC 859 mA with adapter for plug SHUKO/UK/USA – and CABLE for transfer data, 1 pcs HEPA filter and 1 certificate with 2 calibrations (1 for air sampler 1 for selftest) 4770
171 TRIO.BAS MONO BLUETOOTH FILTER air sampler (100 lts/min) Contact plate with Battery charger 100/240VCA 18VDC 859 mA with adapter for plug SHUKO/UK/USA – and CABLE for transfer data, 1 pcs HEPA filter and 1 certificate with 2 calibrations (1 for air sampler 1 for selftest) 4770
173 HEPA FILTER (10xbox) 250
376 STAND UP holder for MINI-MONO-DUO – technopolymer – for table, cart, floor tripod – size 15x11x9h cm 305
521 s/s VERTICAL HOOK with KNOB – for table, cart, floor tripod – compatible with MINI, MONO, DUO, TRIO – size 12x15x25h cm 170
530 s/s WALL/TABLE HOLDER with KNOB – compatible with MINI, MONO, DUO, TRIO – size 2x13x16h cm 160
371 MULTI HOLDER MINI – s/s cart on wheels – 25x35x70h cm – for MONO, DUO, TRIO – stand up holder optional 310
372 MULTI HOLDER MAXI – s/s cart on wheels with TABLE HOLDER and a VERTICAL EXTENSIBLE SUPPORT HOOK – size 25x35x70h cm (min extension 100 – max 210 cm) – for MONO, DUO, TRIO 820
387 MAXI FLOOR TRIPOD – aluminum – (extension min125 cm – max 366 cm) 320
523 s/s FLOOR TRIPOD (extension min 150 cm – max 200 cm) 705
381 Cleanroom bag (5×150) – 750 bags 250
501 IQ, OQ, documents for MONO 400
506 PQ documents for MONO 200
180 s/s TRIO.BAS IN REST 90
175 EASY RACK Contact/Petri 250
395 ROBUSTUS STANDARD carrying case – 48x38x17h cm 190
520 TRIO PRINTER BLUETOOTH – 11×8,5×4,5h cm 530
421 Roll paper 57 mm for TRIO PRINTER (10x box) 21
423 No erasable thermal paper for TRIO PRINTER (10x box) 50
294 Barcode Reader Bluetooth Module 1D – 2D (Optional – APPLICATION FOR GMP/GLP) 720
291 Location preset Barcode tag (10xbox) 90
340 Daily Shift Sterile Aspirating Head (DSHR) for Contact plate – in double sterile bag (20xbox) minimum 4 box 150
341 Daily shift Sterile Aspirating Head (DSHP) for Petri 90 plate – in double sterile bag (20xbox) minimum 4 box 150
Expand Table

User Guide and Instruction manual for TRIO.BAS MONO FILTER

You can request the necessary certificates, documentation, instructions and user guide for TRIO.BAS MONO FILTER using the special form.

You can buy TRIO.BAS MONO FILTER in Latvia at a price starting from 4770 € in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email . TRIO.BAS MONO FILTER price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.