SUTO S230 / S231 Compressed Air Dew Point Transmitter for Ex Applications

The SUTO S230 / S231 Heavy-Duty Dew Point Transmitters provide reliable, long-term stable dew point monitoring for compressed air and gases in harsh and hazardous applications. The fast response time ensures safe and reliable indication whenever dew points are out of valid ranges

			int(2042)
NULL
		

Made in Germany. brand SUTO, model S230 / S231

Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.

price by request

Available

Available

Advantages

Official distributor in Latvia

Time-tested American, European and Asian brands of control and measurent instruments

Advantages

Special price list for organisations

We offer a significant discount for trade organisations and manufacturing companies

Advantages

Worldwide shipping on request

We take care of all logistics and customs clearance. Fast delivery to Baltic countries

Advantages

After-sales service and support

Warranty service and repair, expert assistance in the operation of the instruments

Description of SUTO S230 / S231

S230 For Low Dew Point Applications

The S230 Dew Point Transmitter provides accurate results of a range down to -100 °C Td. This makes it perfectly suitable for special applications where a low dew point needs to be measured.

S231 for Standard Range Applications

S231 Dew Point Transmitter comes with a standard range from -50… +50 °C Td, offering a wide range of dew point monitoring applications for compressed air and gases.

Ex Areas Solution

The optional IECEx approval makes it the perfect tool to be used in explosive environment (Ex area). SUTO’s unique dual sensor technology optimizes sensor sensitivity and accuracy by automatically selecting the ideal sensor type for the situation.

User-Friendly Output Signals

The S230/S231 come ready to use and simple to install with your choice of 4-20mA or Modbus RTU (RS485) outputs. If required, parameters can be quickly monitored through the SUTO service software. The transmitters can also be connected the SUTO S331 (stationary) or S551 (portable) data logger and the data can be transferred for further analysis.

SUTO Exchange Service

The SUTO exchange calibration service helps to eliminate downtime and enables users to have a seamless record of their dew point measurements.

Application

  • Dew point measurement in explosive environments
  • Outdoor / all-weather flow applications
  • Explosive environments

Technical specifications of SUTO S230 / S231

MEASUREMENT
Dew Point
Accuracy ± 1 °C Td (0 … 20 °C Td)
± 2 °C Td (-60 … 0 °C Td)
± 3 °C (-100 … -60 °C Td)
Selectable units °C, °F, bar(g), MPa(g), psi(g), % rH,
g/m³, mg/m³, G/m³ atm., mg/m³ atm., ppm(v), g/kg, °C Td atm.
Measuring range (model depending) S230: -100 … +20 °C Td
S231: -50 … +20 °C Td
Sensor Polymer + QCM
Response time t90 (@ 4l/min) -20 °C Td -> -60 °C Td = < 240 s
-60 °C Td -> -20 °C Td = < 30 s
Temperature
Accuracy 0.3 °C
Measuring range -30 … +70 °C
Sensor NTC
Reference conditions
Selectable conditions Pressure Dew Point,
Atmospheric Dew Point
SIGNAL INTERFACE & SUPPLY
Analog output
Signal 4 … 20 mA (isolated)
Modbus/RTU
Scaling S230: 4 mA = -100 °C Td;
20 mA = +20 °C Td
S231: 4 mA = -50 °C Td;
20 mA = +20 °C Td
Load 250R
Update rate 3 / sec
Fieldbus
Protocol Modbus/RTU
Update rate 1/s
Supply
Voltage supply 15 … 30 VDC
Current consumption 40 mA @ 24 VDC
GENERAL DATA
Konfiguration
PC Software S4C-DP Application
Material
Process connection Stainless steel 1.4301 (SUS 304)
Housing Aluminium alloy
Sensor Polymer, Ceramic
Miscellaneous
Electrical connection Screw terminals
Protection class IP67
Approvals II 2G Ex db ib IIC T4 Gb
II 2D Ex ib tb IIIC T135°C Db
CE
Process connection G 1/2“ thread (ISO 228/1)
Weight 728 g
Operating conditions
Medium Air, Argon, O₂, N₂, CO₂*
Medium quality ISO 8573-1: 4.6.3 or better
Medium temperature -30 … +70 °C
Medium humidity ≤ 20 °C Td
Operating pressure (model depending) -0.1 … 1.6 MPa (S230)
-0.1 … 35 MPa (S231)
Ambient temperature 0 … +50 °C
Ambient humidity 0 … 100 % rH
Storage temperature -20 … +50 °C
Transport temperature -30 … +70 ºC

User Guide and Instruction manual for SUTO S230 / S231

You can request the necessary certificates, documentation, instructions and user guide for SUTO S230 / S231 using the special form.

You can buy SUTO S230 / S231 in Latvia at a favourable price in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email . SUTO S230 / S231 price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.