+371 672 70580

Mon-Fri: 9:00 - 17:00 LV

Email:

KANE988 Boiler & Heat Pump analyser with KANE-LINK

Industrial Boiler, Heat Pump, A/C & Refrigeration Analyser with KANE LINK

			int(22838)
NULL
		

Made in United Kingdom. brand KANE, model 988

Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.

Retailprice from $3 145,86

Available

Available

Advantages

Official distributor in Latvia

Time-tested American, European and Asian brands of control and measurent instruments

Advantages

Special price list for organisations

We offer a significant discount for trade organisations and manufacturing companies

Advantages

Worldwide shipping on request

We take care of all logistics and customs clearance. Fast delivery to Baltic countries

Advantages

After-sales service and support

Warranty service and repair, expert assistance in the operation of the instruments

Description of KANE988

 As KANE958 plus:

  • Double headed pump tests any size boiler
  • O2, CO2 & CO to 10,000ppm with H2 compensation & 10%, HC to 5000ppm
  • 4 toxic gases option
  • Commission & test air conditioning & refrigeration systems – no manifold or hoses required
  • Structured let by, tightness & flue draught tests
  • KANE LINK wireless measurement & future proof promise
  • Large graphic display & memory
  • SEE, SAVE & SEND – KANE LINK transfers tests to KANE LIVE app

Features

  • High capacity water trap & particle filter
  • 10 year warranty under KANE CARE Service & Recertification – our promise to never let you down or your money back

Applications

  • All boilers & heat pumps
  • Combustion performance, efficiency & emissions
  • Boiler & heat pump temperature flow & return
  • Air conditioning & refrigeration system superheat & subcool
  • IAQ – Room CO migration, temperature, RH & airflow

Measures

  • O2 0-21%
  • CO2 0-20%
  • CO 0-10,000ppm H2 compensated & 100,000ppm
  • HC 0-5000ppm
  • Option to measure 4 extra gases
  • Differential temperature -20 to +135°C
  • Differential pressure +/- 160mbar

Calculates

  • CO/CO2 ratio
  • Excess air
  • Combustion efficiency
  • NOx (option)
  • Lambda / AFR 0.8-1.2
  • Superheat & Subcool

Fuel Types

  • 12 standard fuels including: Natural Gas, LPG, Butane, Propane, Light Oil, Heavy Oil & user fuels
  • 40 refrigerants including: R22, R32, R134a, R290 & R410A

Box Contents

  • Industrial Boiler & HVACR analyser supplied with pressure hose, SM50056 high capacity water trap & filter, CHSP5 probe, CU12VDCA21 battery charger, MSC00117 protective pouch & 20106 backpack

Technical specifications of KANE988

PARAMETER RANGE RESOLUTION ACCURACY
Temperature Measurement
Flue Temperature 0 – 600°C 0.1°C ±0.5°C
Inlet temperature (Internal Sensor) 0 – 50°C 0.1°C ±1°C
Inlet temperature (External Sensor) 0 – 600°C 0.1°C ±0.5°C
Flue Gas Measurement
Oxygen 0 – 25% 0.01% ±0.3% Volume
Carbon Monoxide H2 compensated 0 – 10,000ppm 1ppm ±5ppm < 100ppm

+20ppm <400ppm

±5% >400ppm – 2000ppm

+10% >2000ppm – 10,000ppm

Carbon Monoxide High Range 0 – 10% 0.01% ±5% of reading
Nitric Oxide (optional) 0 – 5000ppm 1ppm ±5ppm < 100ppm

+5% >100ppm

Nitrogen Dioxide (optional) 0 – 1000ppm 1ppm ±5ppm < 100ppm

+5% >100ppm

Sulphur Dioxide (optional) 0 – 5000ppm 1ppm ±5ppm < 100ppm

+5% >100ppm

Hydrogen Sulphide (optional) 0 – 200ppm 1ppm ±5ppm < 100ppm

+5% >100ppm

Carbon Dioxide 0 – 40% 0.10% ±5% of reading
Hydrocarbons 0 – 5000ppm 1ppm ±5% of reading
Pressure measurement
Pressure (Differential) ±160mbar 0.1mbar ±0.5% FSD
Velocity: 0-30m/s 1m/s ±0.5% FSD
Calculations
CO/CO2 Ratio 0 – 0.9999 0.0001 ±5% of reading
Efficiency (Net or Gross) 0 – 99.9% 0.10% ±1% of reading
Efficiency High (C) 0 – 119.9% 0.10% ±1% of reading
Excess Air 0 – 119.9% 0.10% ±0.2% of reading
Pre-programmed Fuels
UK, USA & France Natural Gas, Propane, Butane, LPG, Light Oil, Digester Gas & Wood Pellets

Natural Gas, Light Oil, Bio Oil, Coke, LPG, Wood, Town Gas, Butane & Propane

European
Battery Life >5 hours (continuous with pump on)
Certification The KANE988 is independently tested & certified to EN 50379, Parts 1-2 in accordance to 1st German Federal Emission Control Ordinance (Bim5chV) Pending
Operating Conditions
Temperatures 0 – 50°C
Humidity 15 to 90% RH, (non-condensing)
Power Supply Rechargeable batteries, 12v DC @ 2A Charging
Physical Characteristics
Weight Approx. 1.2kg
Dimensions L: 240mm x H: 165mm x W: 65mm
Load More Items

User Guide and Instruction manual for KANE 988

You can request the necessary certificates, documentation, instructions and user guide for KANE 988 using the special form.

You can buy KANE 988 in Latvia at a price starting from3 145,86 $ in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email . KANE 988 price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.