+371 672 70580

Mon-Fri: 9:00 - 17:00 LV

Email:

GEORGIN FKE Level transmitter

  • SMART Transmitter: 4-20mA + HART protocol
  • Span limit : from 10 to 300.000 mmWC
  • Rangeability : 100:1
  • Accuracy: 0.165% (0.1% as an option)
  • Power supply 10.5 to 45VDC
  • Process wetted parts material avec le fluide en 316L st. st., Hastelloy, Monel, Tantalum,
  • Process connection by flange
  • Burnout according NAMUR NE43 recommandations
  • Long term stability: +/- 0.1% of maximum span / 10years

Options:  Local analog or digital indicator, Intrinsically safe version, Explosion proof version, FM, CSA and IECEx certification, Stainless Steel electronic housing

			int(7698)
NULL
		

Made in France. brand GEORGIN, model FKE

Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.

price by request

Available

Available

Advantages

Official distributor in Latvia

Time-tested American, European and Asian brands of control and measurent instruments

Advantages

Special price list for organisations

We offer a significant discount for trade organisations and manufacturing companies

Advantages

Worldwide shipping on request

We take care of all logistics and customs clearance. Fast delivery to Baltic countries

Advantages

After-sales service and support

Warranty service and repair, expert assistance in the operation of the instruments

Description of GEORGIN FKE

The ProcessX level transmitter accurately measures liquid level and transmits a proportional 4 to 20 mA signal.
The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality.

FEATURES

High accuracy:
0.165% accuracy for all calibrated spans is a standard feature. The micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 0.1% accuracy is available as option.

Minimum inventory and design:
Electronics unit, local indicators and electronics housing are interchageable among all ProcessX transmitters.

Minimum environmental influence:
The “Advanced Floating Cell” design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications.

Georgin/HART bilingual communications protocol:
ProcessX series transmitter offers bilingual communications to speak both Georgin proprietary protocol and HART. Any HART compatible devices can communicate with ProcessX.

Application flexibility:
Various options that render the ProcessX suitable for almost any process applications include :

  • Full range of hazardous area approvals,
  • Built-in RFI filter and lightning arrester,
  • 5-digit LCD meter with engineering unit,
  • Stainless steel electronics housing,
  • Wide selection of materials.

Programmable output Linearization Function:
Output signal can be freely programmable. (Up to 14 compensated points at approximation).

Burnout current flexibility (Under Scale: 3.2 to 4.0 mA, Over Scale: 20.0 to 22.5 mA):
Burnout signal level is adjustable using Model FXW or Hand Held Communicator (HHC) to comply with NAMUR NE43.

Dry calibration without reference pressure:
Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration.

Technical specifications of GEORGIN FKE

  • Type : FKE : Smart, 4-20 mA DC + Georgin/Hart digital signal
  • Service : Liquid, gas or vapour
  • Remark : To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications.
  • Lower limit of static pressure (vacuum limit) : Silicone fill sensor : See Fig.1. Fluorinated fill sensor : 66 kPa abs (500 mmHg abs) at temperature below 60 °C. See fig.2
  • Overrange limit :To maximum static pressure limit.
  • Output signal : 4 to 20 mA DC with digital signal superimposed on the analogic signal.
  • Power supply : Transmitter operates on 10.5 V to 45 V DC at transmitter terminals. 10.5 V to 32 V DC for the units with optional arrester

Static pressure, span, and range limit :

Type Static
pressure
Span limit (mmH2O) Range limit
(mmH2O)
Minimum Maximum
FKE 02 Up to flange
rating
10 600  ± 600
FKE 03 32 3200  ± 3200
FKE 05 130 13000  ± 13000
FKE 06 500 50000  ± 50000
FKE 08 3000 300000  ± 300000
Load More Items

User Guide and Instruction manual for GEORGIN FKE

You can request the necessary certificates, documentation, instructions and user guide for GEORGIN FKE using the special form.

You can buy GEORGIN FKE in Latvia at a favourable price in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email . GEORGIN FKE price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.