Options: Local analog or digital indicator, Intrinsically safe version, Explosion proof version, FM, CSA and IECEx certification, Stainless Steel electronic housing
Made in France. brand GEORGIN, model FKE
Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.
price by request
Available
Official distributor in Latvia
Time-tested American, European and Asian brands of control and measurent instruments
Special price list for organisations
We offer a significant discount for trade organisations and manufacturing companies
Worldwide shipping on request
We take care of all logistics and customs clearance. Fast delivery to Baltic countries
After-sales service and support
Warranty service and repair, expert assistance in the operation of the instruments
The ProcessX level transmitter accurately measures liquid level and transmits a proportional 4 to 20 mA signal.
The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality.
FEATURES
High accuracy:
0.165% accuracy for all calibrated spans is a standard feature. The micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 0.1% accuracy is available as option.
Minimum inventory and design:
Electronics unit, local indicators and electronics housing are interchageable among all ProcessX transmitters.
Minimum environmental influence:
The “Advanced Floating Cell” design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications.
Georgin/HART bilingual communications protocol:
ProcessX series transmitter offers bilingual communications to speak both Georgin proprietary protocol and HART. Any HART compatible devices can communicate with ProcessX.
Application flexibility:
Various options that render the ProcessX suitable for almost any process applications include :
Programmable output Linearization Function:
Output signal can be freely programmable. (Up to 14 compensated points at approximation).
Burnout current flexibility (Under Scale: 3.2 to 4.0 mA, Over Scale: 20.0 to 22.5 mA):
Burnout signal level is adjustable using Model FXW or Hand Held Communicator (HHC) to comply with NAMUR NE43.
Dry calibration without reference pressure:
Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration.
Static pressure, span, and range limit :
Type | Static pressure |
Span limit (mmH2O) | Range limit (mmH2O) |
|
Minimum | Maximum | |||
FKE 02 | Up to flange rating |
10 | 600 | ± 600 |
FKE 03 | 32 | 3200 | ± 3200 | |
FKE 05 | 130 | 13000 | ± 13000 | |
FKE 06 | 500 | 50000 | ± 50000 | |
FKE 08 | 3000 | 300000 | ± 300000 |
You can request the necessary certificates, documentation, instructions and user guide for GEORGIN FKE using the special form.
You can buy GEORGIN FKE in Latvia at a favourable price in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email olil@olil.lv. GEORGIN FKE price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.
See also: Level sensors & transmitters