ZETRON TA-201E Total Organic Carbon Analyser

The TA-201E analyzer is designed for separate determination of total carbon (TC) and inorganic carbon (IC) in water, followed by calculation of total organic carbon (TOC) content. The instrument uses the high-temperature catalytic oxidation method and is equipped with a high-precision CO₂ detector (NDIR). It provides rapid analysis, high automation level, flow stability, and enhanced safety. Suitable for analyzing samples with high organic carbon content.

			int(23256)
NULL
		

Made in China. brand ZETRON, model TA-201E

Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.

price by request

Available

Available

Advantages

Official distributor in Latvia

Time-tested American, European and Asian brands of control and measurent instruments

Advantages

Special price list for organisations

We offer a significant discount for trade organisations and manufacturing companies

Advantages

Worldwide shipping on request

We take care of all logistics and customs clearance. Fast delivery to Baltic countries

Advantages

After-sales service and support

Warranty service and repair, expert assistance in the operation of the instruments

Description of ZETRON TA-201E

TA-201E adopts the high-temperature catalytic combustion oxidation method, the specimen together with the purification gas (high purity oxygen) are introduced into the hightemperature combustion tube and the low-temperature reaction tube respectively, the specimen through the high-temperature combustion tube is catalytically oxidised by the high temperature, and the organic carbon and inorganic carbon therein are converted into carbon dioxide, and the inorganic carbon therein is decomposed into carbon dioxide after the acidification of the specimen through the low-temperature reaction tube; the carbon dioxide produced by both reaction tubes is introduced into the non-dispersive infrared gas detector NDIR in turn through carrier gas transport, and COThe carbon dioxide produced in the two reaction tubes is sequentially introduced into the non-dispersive infrared gas detector (NDIR) through gas transport, and CO₂ is detected.

Thus, the total carbon (TC) and inorganic carbon (IC) in the water are measured separately.The difference between TC and IC is the total organic carbon (TOC). That is: TOC = TC – IC

Features

  • 1. High-temperature catalytic oxidation can efficiently oxidize difficult-to-digest organic carbon, making the product easy to analyze high-concentration TOC samples;
  • Rapid analysis (1-4 minutes);
  • Higher safety, the combustion furnace heating adopts multiple protections, and the overheating protection circuit is independent of the temperature control system. Overheating can automatically cut off the heating to ensure product safety;
  • Real-time flow monitoring to maintain flow stability and ensure data reliability;
  • The pipeline can be cleaned and purged in all directions. The internal circuit can be cleaned according to the needs and operating requirements, which greatly reduces the failure rate and instrument maintenance time;
  • The instrument automatically discharges waste, automatically discharges and feeds acid, and the acid inlet amount is controlled stably;
  • Less sample and reagent consumption, each measurement requires 0.5μL of high-purity water, 2ml of acid reagent (for IC testing), and about 2000ml of high-purity oxygen (under standard conditions, flow rate 100ml/min, ventilation time 20min.);
  • The CO₂ detection of the NDIR detector has good linearity and high accuracy. The CO₂ signal is converted into a peak curve, and then the built-in data processor calculates the TOC value (the difference between TC and IC);
  • The catalytic combustion oxidation method has strong oxidation ability and can oxidize almost all organic matter with stable performance. The 680℃ combustion method is almost below the melting point of all salts, which can extend the life of the catalyst and combustion tube, which is especially important when the measurement object is a water sample containing salt;
  • The instrument uses a high-resolution 7-inch touch wide screen and adopts an intelligent system for easy operation.

Application
Determination of total organic carbon (TOC) in surface water, groundwater, domestic sewage, industrial wastewater, applied to environmental monitoring, urban water supply and drainage, disease control, chemical power and other industries.

Technical specifications of ZETRON TA-201E

Measurement range 0~1000mg/L (non-dilution state), dilution state can reach
0~30000mg/L
Repeatability ≤ 3%
Indication error TC; ±0.1%F.S or ±5% (the larger one)
IC; ±0.1%F.S or ±4% (the larger one)
Linearity R2≥99.9%
Lower detection limit 0.5mg/L
Analysis time 2~4min
Injection volume 10μL~500μL
External storage U disk
Power supply AC 220V±10% 50/60Hz (reliable grounding required)
Power 1000W when the electric furnace is heated
Ambient temperature 0~40℃
Relative humidity 10~85%
Setting location Indoor
Gas source high-purity oxygen (≥99.999%)
High purity Water Carbon dioxide-free water (TOC≤0.5mg/L)
Acid reagent 10% phosphoric acid
Instrument placement There must be 20cm of space around for heat dissipation, and no items can be stacked on top
Combustion temperature 680℃~1200℃
Expand Table

User Guide and Instruction manual for ZETRON TA-201E

You can request the necessary certificates, documentation, instructions and user guide for ZETRON TA-201E using the special form.

You can buy ZETRON TA-201E in Latvia at a favourable price in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email . ZETRON TA-201E price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.