+371 672 70580

Mon-Fri: 9:00 - 17:00 LV

Email:

TSI 3090 Engine Exhaust Particle Sizer (EEPS)

Simply the best tool for measuring particle emissions and characterizing exhaust aftertreatment devices during transient engine cycles

			int(15505)
NULL
		

Made in USA. brand TSI, model 3090

Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.

price by request

Available

Available

Advantages

Official distributor in Latvia

Time-tested American, European and Asian brands of control and measurent instruments

Advantages

Special price list for organisations

We offer a significant discount for trade organisations and manufacturing companies

Advantages

Worldwide shipping on request

We take care of all logistics and customs clearance. Fast delivery to Baltic countries

Advantages

After-sales service and support

Warranty service and repair, expert assistance in the operation of the instruments

Description of TSI 3090

The Engine Exhaust Particle Sizer™ (EEPS™) 3090 is a fast-response, high-resolution spectrometer that measures very low particle number concentrations in diluted exhaust. It offers the fastest time resolution available—10 times per second—which makes it well-suited for dynamic and transient tests. It measures the size distribution and number concentration of engine exhaust particle emissions in the range from 5.6 to 560 nanometers, covering the entire range of interest.

Applications

  • Engine exhaust and after treatment characterization
  • Brake dust and tire wear emissions

Features and Benefits

  • Measures particles from 5.6 to 560 nm
  • 10 Hz data collection captures transient events in real-time
  • Comprehensive software for data collection and analysis
  • Selectable matrices tailored to application for more accurate measurement (see Application Note EEPS-005)
  • Housed in a single cabinet that weighs just 32 kg
  • Four configurable analog outputs (see Application Note EEPS-001 for details)
  • Optional AK serial command protocol for emissions test system integration with host controller

The EEPS™ spectrometer was developed for continuous measurement of entire test cycles. For example, users might use this instrument to observe filter loading or to reduce emissions below certain limits during engine calibration. With real-time data collection and display capabilities, users can visualize and study the dynamic behavior of particle emissions that occur during transient test cycles. This includes particles produced as a result of changes in engine speed, torque, or load, or particle emissions that occur during the first few seconds of a cold start or during regeneration of a diesel particulate filter (DPF).

Every unit is supplied with software that is unmatched in the industry. The software combines data collection and analysis in a single program for ease of use, so there is no need for external processing in spreadsheets.

Technical specifications of TSI 3090

Operating Features
Particle Size Range 5.6 to 560 nm
Particle Size Resolution 16 channels per decade (32 total)
Electrometer Channels 22 active, 24 total
Charger Mode of Operation Dual unipolar diffusion chargers
Inlet Cyclone 50% Cutpoint 1 μm
Time Resolution 10 size distributions/sec
Flow Rates
Sample Flow 10 L/min
Sheath Air 40 L/min
Environmental Conditions
Inlet Sample Temperature 10 to 52°C
Operating Temperature 0 to 40°C
Storage Temperature -20 to 50°C
Atmospheric Pressure
Correction Range
70 to 103 kPa (700 to 1034 mbar)
Humidity 0 to 90% RH (noncondensing)
Communications
User Interface Rotary knob and display,
EEPS software
Front-Panel Display 6.4-inch color VGA LCD
Operating System Required Windows® 7, 8, or 10.
(32-bit or 64-bit) operating systems
Communications 9-pin RS-232
Electrical Features
Analog Input Two analog input channels,
0 to 10 V
Analog Output Four user-configurable analog
outputs (see Application Note
EEPS-001 for details)
Trigger Input Two trigger input channels,
potential-free contact closure
or 3.3 V pulled to GND
Trigger Output Trigger output channel,
potential-free contact closure
Physical Features
Dimensions (H x W x D) 70.4 × 34.3 × 43.9 cm
(27.7 × 13.5 × 17.3 in)
Weight 32 kg (70 lb)
Sample Inlet 3/8-in. OD (without inlet cyclone)
Cyclone Inlet 3/8-in. OD
Exhaust/Outlet 3/8-in. OD
Power Requirements 100 to 240 VAC, 50/60 Hz, 250 W
Acknowledgments
The Engine Exhaust Particle Sizer™ (EEPS™) spectrometer was developed by TSI® under license from Airel, Ltd. of Tartu, Estonia. We gratefully acknowledge the contributions from the dedicate

User Guide and Instruction manual for TSI 3090

You can request the necessary certificates, documentation, instructions and user guide for TSI 3090 using the special form.

You can buy TSI 3090 in Latvia at a favourable price in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email . TSI 3090 price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.