Applications
System Specifications | |
Detector Type | Infrared absorption type |
Measuring Range | 0 to 100% LEL 0 to 100% by volume (methane only) |
Gases | Methane, propane, ethane, ethylene, butane, hexane, pentane Consult factory for other gases |
Detector Life | greater than 5 years |
Accuracy @ 25°C |
± 3% LEL at ≤ 50% LEL reading ± 5% LEL at > 50% LEL reading |
Zero drift |
< 2% per year |
Response time With Splash Guard |
T50 ≤ 1.5 s, T60 ≤ 1.5 s, T90 ≤ 3 s
Except ethylene where T60 ≤ 2 s and T90 ≤ 4 s |
Readout / Relay Display modules |
DC110; TA102A; IR4000 display, and relay alarms |
Accessories | Junction box, duct mount junction box,calibration cup, flow block, splash guard, rain guard, portable purge calibrator |
Classification | Class I, Zone 1, IIB + H2 (Ta=-40° C to +75° C) Ex d, IIB + H2 T5 gb Ex tb IIIC, T100° C Db, IP66 (Ta=-60° C to +75° C) |
Warranty | Two years |
Approvals | ATEx, IECEx, MED, DNV gL, CE, FM 6310, 6320 and CSA 22.2 No. 152 EN 60079-29-1 Performance Approved HART Registered, SIL 3 suitable FM Certified to IEC 61508 |
Environmental Specifications |
|
Operating temperature range FM, CSA, GOST-R ATEx, IECEx ETHYLENE |
-40° F to +167° F (-40° C to +75° C) -76° F to +167° F (-60° C to +75° C) -40° F to +140° F (-40° C to +60° C) |
Storage temperature range |
-58° F to +185° F (-50° C to +85° C) |
Oparating humidity range |
10% to 95% RH, non-condensing |
Electrical Specifications |
|
Input power |
20-36 VDC @ 200 mA max. 24 VDC nominal |
Analog signal START UP, FAULT (non-HART) START UP, FAULT (HART)* CAL, ZERO, GAS CHECk* DIRTy OPTICS* 0 TO 100% LEL OVER-RANGE |
0-21.7 mA (600 ohms max.) 0 mA 1.25 mA 1.5 mA 2.0 mA 4 to 20 mA (proportional) 20 to 21.7 mA |
EMC |
Complies with EN 50270, EN 61000-6-4 |
Cable requirements |
Max. distance between IR400 and power source @ 24 VDC nominal (20 ohm loop resistance): 14 AWg (2.0 mm2) – 3600 ft (1100 m) Max. distance for analog output (500 ohms max): 14 AWg (2.0 mm2) – 9000 ft. (2740 m) |
Faults monitored |
Re-calibration error, EPROM checksum error, optics failure/blockage; low supply voltage, EEPROM checksum error, reference or active lamp failure, heater failure, time to re-zero unit, short circuit on CAL_IO wire |
RS-485 output |
Modbus RTU, suitable for linking up to 128 units or up to 247 units with repeaters |
Baud rate |
2400, 4800, 9600, or 19200 BPS |
Hart (optional)
|
HART 6, HART Device Descriptor available. AMS aware |
Wireless communication |
Available with ELPRO Technologies wireless devices |
Mechanical Specifications |
|
Diameter |
2.9” (74 mm) |
Length |
8.87” (225 mm) |
Weight ALUMINUM STAINLESS STEEL |
3 lbs (1.35 kg) 6 Ibs (2.7 kg) |
Mounting | ¾” NPT |
Ingress protection |
Type 4x, IP66 |
Housing |
Aluminum 6061-T6 alloy or 316 stainless steel |
Standard configuration |
IR400-0-01-1-2-0-1-0 Methane, 4-20 mA, Modbus, aluminum, splashguard w/screen, no junction box |
You can request the necessary certificates, documentation, instructions and user guide for MSA Safety IR400 using the special form.
You can buy MSA Safety IR400 in Latvia at a favourable price in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email olil@olil.lv. MSA Safety IR400 price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.
See also: Gas detectors & analysers