This sensor is used for temperature measurement of liquid and gaseous media. The temperature sensor design (replaceable measuring insert) is suitable for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the the bottom of the sensor thermowell.
- Temperatura range -200÷550ºC RTD
- sensing element: Pt100/Pt500/Pt1000 resistor
- process connection with G1/2 or M20x1,5 thread
- connection head type BA IP55, – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
- measuring insert: pipe or mineral insulated version
price by request
This sensor is used for temperature measurement of liquid and gaseous media. The temperature sensor design (replaceable measuring insert) is suitable for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell.
- Temperatura range -40÷1150ºC K
- process connection with G1/2 or M20x1,5 thread
- connection head type BA IP55, – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
- measuring insert: pipe or mineral insulated version
price by request
Temperature sensor applied in industrial pipelines, pressure and other tanks for temperature measurement of liquids and gases. Sensing element is placed directly in the thermowell.
- Temperatura range -40÷600ºC TC
- sensing element: J thermocouple
- process connection with G1/2 or M20x1,5 thread
- connection head type MA IP54 – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
price by request
Temperature sensor suitable for measurement primarily in heat-treating furnaces, boiler houses, etc. This sensor has double protection tube: inner ceramic and outer made of heat resistant steel.
- Temperatura range: -40÷1200ºC R
- sensing element: S thermocouple
- connection head type AA IP53 – 40÷100ºC
- sheath material: steel 1.4762, 1.4841, and ceramic
- temperature transmitter can be mounted in a connection head
price by request
Temperature sensor suitable for measurement of liquid glass. It has ceramic protection tube and dusted platinum layer. This sensor can be equipped with three thermocouplesmeasuring temperature on different depths.
- Temperatura range: 0÷1600ºC S
- sensing element: S thermocouple
- ceramic tube material: corundum 799
- connection head type AA, IP53, -40÷150ºC
- protective coat material Pt, PtRh10, PtRh20
- temperature transmitter can be mounted in a connection head
price by request
Temperature sensor suitable for measurement in hard-to-reach places and in applications requiring the use of flexible sensors with small diameters, and low thermal inertia.
- performance with head BA
- corrosion resistance during high temperature oxidation process of carburising and chlorination (ammonia and nitrides presence)
- material OMEGACLAND XL
price by request
Temperature sensor suitable for measurement in hard-to-reach places and in applications requiring the use of flexible sensors with small diameters, good vibration and shock resistance, and low thermal inertia.
- mounting elements: nickel-plated brass and stainless steel
- straight or angular version
price by request
Temperature sensor suitable for measurement of aggressive liquid and gaseous media, especially in petrochemical and chemical industry (acids, ammonia).
- material: ceramic SILIT SK
- connection head type BA, IP54, -40÷100ºC
- fi tting assembly and extension pipe: stainless steel 1.4541
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- process connection with G1/2 or M20x1,5 thread
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- process connection with G1/2 or M20x1,5, 1/2NPT thread
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
Db IP66
price by request
This sensor is used for temperature measurement of liquid and gaseous media. The temperature sensor design (replaceable measuring insert) is suitable for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the the bottom of the sensor thermowell.
- Temperatura range -40÷550ºC TC
- process connection with G1/2 or M20x1,5 thread
- connection head type BA IP55, – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
- measuring insert: pipe or mineral insulated version
price by request
This sensor is used for temperature measurement of liquid and gaseous media. The temperature sensor design (replaceable measuring insert) is suitable for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell.
- Temperatura range -40÷700ºC J
- sensing element: J thermocouple
- process connection with G1/2 or M20x1,5 thread
- connection head type BA IP55, – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
- measuring insert: pipe or mineral insulated version
price by request
Temperature sensor applied in industrial pipelines, pressure and other tanks for temperature measurement of liquids and gases. Sensing element is placed directly in the thermowell.
- Temperatura range -40÷600ºC TC
- sensing element: K thermocouple
- process connection with G1/2 or M20x1,5 thread
- connection head type MA IP54 – 40÷100ºC
- sheath material: acid-resistant steel 1.4541
- temperature transmitter can be mounted in a connection head
price by request
Temperature sensor suitable for measurement primarily in heat-treating furnaces, boiler houses, etc. This sensor has double protection tube: inner ceramic and outer made of heat resistant steel.
- Temperatura range: -40÷1200ºC K
- sensing element: S thermocouple
- connection head type AA IP53 – 40÷100ºC
- sheath material: steel 1.4762, 1.4841, and ceramic
- temperature transmitter can be mounted in a connection head
price by request
Temperature sensor suitable for measurement of liquid glass. It has ceramic protection tube and dusted platinum layer. This sensor can be equipped with three thermocouplesmeasuring temperature on different depths.
- Temperatura range: 600÷1700ºC B
- sensing element: B thermocouple
- ceramic tube material: corundum 799
- connection head type AA, IP53, -40÷150ºC
- protective coat material Pt, PtRh10, PtRh20
- temperature transmitter can be mounted in a connection head
price by request
Temperature sensor suitable for measurement in hard-to-reach places and in applications requiring the use of flexible sensors with small diameters, and low thermal inertia.
- performance with head NA, IP65
- material stainless steel 1.4541 and INCONEL
price by request
Temperature sensor suitable for measurement in hard-to-reach places and in applications requiring the use of flexible sensors with small diameters, good vibration and shock resistance, and low thermal inertia.
- mounting elements: nickel-plated brass and stainless steel
- straight or angular version
price by request
Temperature sensor suitable for measurement of aggressive liquid and gaseous media, especially in petrochemical and chemical industry (acids, ammonia).
- material: ceramic SILIT SK
- connection head type BA, IP54, -40÷100ºC
- fi tting assembly and extension pipe: stainless steel 1.4541
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. It has a replaceable measuring insert adequate for various industrial applications. Replacement of the measuring insert does not cause the technological installation damage. Spring-loaded insert ensures an excellent connection with the bottom of the sensor thermowell. Temperature sensor has ATEX approval for application in hazardous area: I M1 Ex ia (with connection head N1) II 1/2G Ex ia IIC T6 II 1/2D Ex ia IIIC T85°C cable gland II 2GD Ex eb IIc, Ex ta IIIC (for the cable 5÷10mm)
- process connection with G1/2 or M20x1,5 thread
- connection head type aluminium XE-DANA (S1-standard), XE-DAND (S2),
XE-DANAW (W1), XE-DANDW (W2) or stainless XE-BE (N1), IP65 - sheath material: acid-resistant steel 1.4541
- cable gland ATEX II GD IP65 (for cable 5÷10 mm)
- Exi acc. to ATEX
price by request
- process connection with G1/2 or M20x1,5 thread
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68,cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price by request
Temperature sensor suitable for measurement of liquid and gaseous media. Temperature sensor has ATEX approval for application in hazardous area: I M2 Ex d I Mb (with connection head NS) II 2G Ex d IIC T6 Gb II 2D Ex t IIIC T85ºC Db IP66
- aluminium: XD-AD (AS1 – one cable gland, AS2 – two cable glands)
- aluminium, cover with window: XD-ADwin (AS3 – one cable gland, AS4 – two cable glands)
- stainless steel: XD-SD (NS1 – one cable gland, NS2 – two cable glands)
- sheath material: acid-resistant steel 1.4541, 1.4571, 2.4816
- cable gland: ATEX II 2 GD; ATEX I M2; IP 66÷68, cable diameter: 3÷14,3 mm (standard 6,1÷11,7)
- Exd acc. to ATEX
price by request