Made in Germany. brand Leitenberger, model LDW-P
Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.
Retail price from $7400
Available
Official distributor in Latvia
Time-tested American, European and Asian brands of control and measurent instruments
Special price list for organisations
We offer a significant discount for trade organisations and manufacturing companies
Worldwide shipping on request
We take care of all logistics and customs clearance. Fast delivery to Baltic countries
After-sales service and support
Warranty service and repair, expert assistance in the operation of the instruments
Proven primary standard
Pressure balances / deadweight tester are the most accurate devices available on the market for the calibration of electronic or mechanical pressure measuring instruments. The direct measurement of the pressure (p = F/A), as well as the use of high quality materials allow a very small measurement uncertainty in combination with an excellent long-term stability of 5 years (recommendation according to the German Calibration Service (DAkkS)). Pressure balances / deadweight tester have been used for years in factory and calibration laboratories of industry, national institutes and research institutes.
Autarkic operation
Due to the integrated pressure generation (for measuring ranges up to 10 bar) as well as the purely mechanical measuring principle, the LR-Cal LDW-P pressure balance is also ideally suited for on-site use, maintenance and service.
Grundprinzip
The mass support is proportional to the targeted pressure and is achieved by optimally graduated disc weights. These disc weights are manufactured as standard to the standard acceleration of gravity of 9.80665 m/s², but can also be optionally adapted to their specific location of use and also DAkkS calibrated.
Simple operation
In the stable basic unit, even large test volumes can be easily filled and compressed in the version up to 7 bar with the integrated priming pump. For further pressure build-up, a very precisely adjustable spindle pump with internally rotating spindle is installed. Ranges from 25 bar (up to 120 bar) have a connection for an external pressure supply (e.g. nitrogen bottle with pressure reducer).
As soon as the measuring system is in a floating state, there is a balance of forces between the pressure and the mass supports. Due to the excellent workmanship of the system, this pressure remains stable for several minutes, so that the pressure values for comparative measurement or even more extensive adjustment work can be carried out on the test specimen without any problems.
Two basic device versions
The LR-Cal LDW-P deadweight tester is supplied in one of the following two variants depending on the measuring range:
NOTE: When used with vacuum piston cylinder system, this second version with connection for external pressure/vacuum supply MUST be used.
As standard, the basic units are equipped with a connection for the piston-cylinder system with thread 3/4″ BSP male. A quick-action clamping fixture for the piston-cylinder system is available as an option (mandatory for vacuum range). This allows the piston-cylinder system to be changed quickly and safely without tools.
The test specimen is connected to a quick-connect system without tools. Due to the free-running knurled nut, the test specimens can be aligned as desired. A threaded insert with a 1/2″ BSP thread is included as standard. Further threaded inserts are optionally available, with which all common pressure measuring devices can be connected.
Special features:
Applications:
| Execution | |||||||
|---|---|---|---|---|---|---|---|
| for ranges up to 7 bar | Integrated pressure generation (pre-pressure pump, spindle pump) | ||||||
| for franges from 25 bar and vacuum | Connection for external pressure/vacuum supply | ||||||
| Connections / media |
|||||||
| Connection piston-cylinder | M30 x 2 male thread Optional: Quick release connector (changement of piston without tools) |
||||||
| Connection unit under test | Quit fit 1/2″ BSP female, rotating, exchangeable | ||||||
| Pressure transmission medium | clean, dry, non-corrosive gases (e.g. air, nitrogen) | ||||||
| External port for sourcing pressure/vacuum | 6 mm SWAGELOK® tube fitting, max. 100% of the measuring range used (only for version for external pressure supply) | ||||||
| Materials | |||||||
| Piston | Ranges 0.015…1 bar to 0.1…7 bar + 0.2…15 to bis 1…100 psi: Chrome steell Ranges 0,2…25 bar + 3…400 psi: Tungston carbide Ranges 1…70 bar bis 1…120 bar + 15…1,000 psi und 10…1,600 psi: Chrome steel |
||||||
| Cylinder | Ranges 0,015…1 bar to 0,1…7 bar + 0,2…15 psi bis 1…100 psi: High-alloy heat-treated stainless steel Ranges 0,2…25 bar + 3…400 psi: Tungston carbide Ranges 1…70 bar to 1…120 bar + 15…1.000 psi to 10…1.600 psi: Bronze |
||||||
| Mass set | Stainless steel, non-magnetic | ||||||
| Pipings in the basement | Version with integrated pressure supply: Polyurethane hose 4 x 0.75 mm Version for ext. pressure supply: Stainless steel 1.4571, 3 x 1 mm |
||||||
| Operating conditions |
|||||||
| Operating temperature | °C | 18…28 | |||||
| Weight | |||||||
| Basement | kg | 18.0 (19.0 with optional quick release connection) | |||||
| Dimensions | |||||||
| Basement | mm | W 401 x D 375 x H 265 | |||||
| Case for mass set | mm | W 400 x D 310 x H 310 each case | |||||
| Certificate | |||||||
| Calibration | Inspection certificate 3.1 according to DIN EN 10204 Optional DAkkS certificate, traceable and accredited according to ISO 17025 |
||||||
| CE conformity | No certificate required | ||||||
| Photo | Model | Description |
|---|---|---|
![]() |
LDW-P-FMS | Additional finer set of weights to increase the “resolution”.
In addition to the standard weight set. |
![]() |
LDW-FMS-F1 | Fine incremental weight set class F1 1 mg bis 50 g |
![]() |
LDW-FMS-M1 | Fine incremental weight set class M1 1 mg bis 50 g |
![]() |
LDW-ADAPTER-BSP | Set of BSP adapter for test piece connection to 1/8″ + 1/4″ + 3/8″ + 1/2″ BSP (1 x included in the scope of supply of the device) |
![]() |
LDW-ADAPTER-NPT | Set of NPT adapter for test item connection to 1/8″ + 1/4″ + 3/8″ + 1/2″ NPT |
![]() |
CPB5000-WA90 | 90° elbow connector e.g. for connecting pressure gauges with rear pressure connection to the test connection of the device |
![]() |
CPB5000-TV-1000 | Oil/water to air separator, max. 1,000 bar. Thus, test specimens exposed to oil or water can be tested/calibrated with the pneumatic pressure balance. |
| Model | Description | Price |
|---|---|---|
| LDW-P-B-00001-G015 | LR-Cal LDW-P – pneumatic, for small pressures, with integrated manual pressure source. Uncertainty ±0.015% of measured value. Range: 0,015 … 1 bar | 7400 $ |
| LDW-P-B-00002-G015 | LR-Cal LDW-P – pneumatic, for small pressures, with integrated manual pressure source. Uncertainty ±0.015% of measured value. Range: 0,015 … 2 bar | 7400 $ |
| LDW-P-B-00007-G015 | LR-Cal LDW-P – pneumatic, for small pressures, with integrated manual pressure source. Uncertainty ±0.015% of measured value. Range: 0,1 … 7 bar | 7400 $ |
| LDW-P-P-00015-G015 | LR-Cal LDW-P – pneumatic, for small pressures, with integrated manual pressure source. Uncertainty ±0.015% of measured value. Range: 0,2 … 15 psi | 7800 $ |
| LDW-P-P-00030-G015 | LR-Cal LDW-P – pneumatic, for small pressures, with integrated manual pressure source. Uncertainty ±0.015% of measured value. Range: 0,2 … 30 psi | 7800 $ |
| LDW-P-P-00100-G015 | LR-Cal LDW-P – pneumatic, for small pressures, with integrated manual pressure source. Uncertainty ±0.015% of measured value. Range: 1 … 100 psi | 7800 $ |
| LDW-P-B-00001-G008 | LR-Cal LDW-P – pneumatic, for small pressures, with integrated manual pressure source. Uncertainty ±0.008% of measured value. Range: 0,015 … 1 bar | 8700 $ |
| LDW-P-B-00002-G008 | LR-Cal LDW-P – pneumatic, for small pressures, with integrated manual pressure source. Uncertainty ±0.008% of measured value. Range: 0,015 … 2 bar | 8900 $ |
| LDW-P-B-00007-G008 | LR-Cal LDW-P – pneumatic, for small pressures, with integrated manual pressure source. Uncertainty ±0.008% of measured value. Range: 0,1 … 7 bar | 8900 $ |
| LDW-P-P-00015-G08 | LR-Cal LDW-P – pneumatic, for small pressures, with integrated manual pressure source. Uncertainty ±0.008% of measured value. Range: 0,2 … 15 psi | 9000 $ |
| LDW-P-P-00030-G008 | LR-Cal LDW-P – pneumatic, for small pressures, with integrated manual pressure source. Uncertainty ±0.008% of measured value. Range: 0,2 … 30 psi | 9300 $ |
| LDW-P-P-00100-G008 | LR-Cal LDW-P – pneumatic, for small pressures, with integrated manual pressure source. Uncertainty ±0.008% of measured value. Range: 1 … 100 psi | 9300 $ |
| LDW-PK-B-00001-G015 | Additional piston-/cylinder-units for above mentioned PNEUMATIC models with integrated manual pressure source. Uncertainty ±0.015% of measured value. Range: 0,015 … 1 bar | 3100 $ |
| LDW-PK-B-00002-G015 | Additional piston-/cylinder-units for above mentioned PNEUMATIC models with integrated manual pressure source. Uncertainty ±0.015% of measured value. Range: 0,015 … 2 bar | 3200 $ |
| LDW-PK-B-00007-G015 | Additional piston-/cylinder-units for above mentioned PNEUMATIC models with integrated manual pressure source. Uncertainty ±0.015% of measured value. Range: 0,1 … 7 bar | 3200 $ |
| LDW-PK-P-00015-G015 | Additional piston-/cylinder-units for above mentioned PNEUMATIC models with integrated manual pressure source. Uncertainty ±0.015% of measured value. Range: 0,2 … 15 psi | 3100 $ |
| LDW-PK-P-00030-G015 | Additional piston-/cylinder-units for above mentioned PNEUMATIC models with integrated manual pressure source. Uncertainty ±0.015% of measured value. Range: 0,2 … 30 psi | 3200 $ |
| LDW-PK-P-00100-G015 | Additional piston-/cylinder-units for above mentioned PNEUMATIC models with integrated manual pressure source. Uncertainty ±0.015% of measured value. Range: 1 … 100 psi | 3200 $ |
| LDW-PK-B-00001-G008 | Additional piston-/cylinder-units for above mentioned PNEUMATIC models with integrated manual pressure source. Uncertainty ±0.008% of measured value. Range: 0,015 … 1 bar | 4400 $ |
| LDW-PK-B-00002-G008 | Additional piston-/cylinder-units for above mentioned PNEUMATIC models with integrated manual pressure source. Uncertainty ±0.008% of measured value. Range: 0,015 … 2 bar | 4700 $ |
| LDW-PK-B-00007-G008 | Additional piston-/cylinder-units for above mentioned PNEUMATIC models with integrated manual pressure source. Uncertainty ±0.008% of measured value. Range: 0,1 … 7 bar | 4700 $ |
| LDW-PK-P-00015-G008 | Additional piston-/cylinder-units for above mentioned PNEUMATIC models with integrated manual pressure source. Uncertainty ±0.008% of measured value. Range: 0,2 … 15 psi | 4400 $ |
| LDW-PK-P-00030-G008 | Additional piston-/cylinder-units for above mentioned PNEUMATIC models with integrated manual pressure source. Uncertainty ±0.008% of measured value. Range: 0,2 … 30 psi | 4700 $ |
| LDW-PK-P-00100-G008 | Additional piston-/cylinder-units for above mentioned PNEUMATIC models with integrated manual pressure source. Uncertainty ±0.008% of measured value. Range: 1 … 100 psi | 4700 $ |
| LDW-P-MS-0001 | Sets of weights for this additional piston-/cylinder-units. Range: 0,015…1 bar | 1900 $ |
| LDW-P-MS-0002 | Sets of weights for this additional piston-/cylinder-units. Range: 0,015…2 bar | 1900 $ |
| LDW-P-MS-0007 | Sets of weights for this additional piston-/cylinder-units. Range: 0,1…7 bar | 1900 $ |
| LDW-P-MS-0015-PSI | Sets of weights for this additional piston-/cylinder-units. Range: 0,2…15 psi | 2345 $ |
| LDW-P-MS-0030-PSI | Sets of weights for this additional piston-/cylinder-units. Range: 0,2…30 psi | 2345 $ |
| LDW-P-MS-0100-PSI | Sets of weights for this additional piston-/cylinder-units. Range: 1…100 psi | 2345 $ |
| LDW-P-B-00000-G015 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: -1 … -0,015 bar (vacuum) | 9200 $ |
| LDW-P-B-00025-G015 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: 0,2 … 25 bar | 8000 $ |
| LDW-P-B-00070-G015 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: 1 … 70 bar | 8800 $ |
| LDW-P-B-00120-G015 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: 1 … 120 bar | 10100 $ |
| LDW-P-P-00000-G015 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: -15 … -0,2 psi (vacuum) | 9500 $ |
| LDW-P-P-00400-G015 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: 3 … 400 psi | 8400 $ |
| LDW-P-P-01000-G015 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: 15 … 1000 psi | 9000 $ |
| LDW-P-P-01600-G015 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: 10 … 1600 psi | 10300 $ |
| LDW-P-B-00000-G008 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: -1 … -0,015 bar (vacuum) | 10800 $ |
| LDW-P-B-00025-G008 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: 0,2 … 25 bar | 9700 $ |
| LDW-P-B-00070-G008 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: 1 … 70 bar | 10400 $ |
| LDW-P-B-00120-G008 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: 1 … 120 bar | 12300 $ |
| LDW-P-P-00000-G008 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: -15 … -0,2 psi (vacuum) | 10800 $ |
| LDW-P-P-00400-G008 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: 3 … 400 psi | 10000 $ |
| LDW-P-P-01000-G008 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: 15 … 1000 psi | 10600 $ |
| LDW-P-P-01600-G008 | R-Cal LDW-P – pneumatic, for vacuum or higher pressures, with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: 10 … 1600 psi | 12600 $ |
| LDW-PK-B-00000-G008 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: -1 … -0,015 bar (vacuum) | 4700 $ |
| LDW-PK-B-00025-G015 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: 0,2 … 25 bar | 3600 $ |
| LDW-PK-B-00070-G015 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: 1 … 70 bar | 3700 $ |
| LDW-PK-B-00120-G015 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: 1 … 120 bar | 4900 $ |
| LDW-PK-P-00000-G015 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: -15 … -0,2 psi (vacuum) | 4700 $ |
| LDW-PK-P-00400-G015 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: 3 … 400 psi | 3600 $ |
| LDW-PK-P-01000-G015 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: 15 … 1000 psi | 3700 $ |
| LDW-PK-P-01600-G015 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.015% of measured value. Range: 10 … 1600 psi | 4900 $ |
| LDW-PK-B-00000-G008 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: -1 … -0,015 bar (vacuum) | 6000 $ |
| LDW-PK-B-00025-G008 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: 0,2 … 25 bar | 5200 $ |
| LDW-PK-B-00070-G008 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: 1 … 70 bar | 5200 $ |
| LDW-PK-B-00120-G008 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: 1 … 120 bar | 7000 $ |
| LDW-PK-P-00000-G008 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: -15 … -0,2 psi (vacuum) | 6000 $ |
| LDW-PK-P-00400-G008 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: 3 … 400 psi | 5200 $ |
| LDW-PK-P-01000-G008 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: 15 … 1000 psi | 5200 $ |
| LDW-PK-P-01600-G008 | Add piston-/cylinder-units for above mentioned PNEUMATIC models with connector for external pressure/vacuum source. Uncertainty ±0.008% of measured value. Range: 10 … 1600 psi | 7000 $ |
| LDW-P-MS-0001 | Sets of weights for this additional piston-/cylinder-units. Range: -1…-0,015 bar (vacuum) | 1900 $ |
| LDW-P-MS-0025 | Sets of weights for this additional piston-/cylinder-units. Range: 0,2…25 bar | 1900 $ |
| LDW-P-MS-0070 | Sets of weights for this additional piston-/cylinder-units. Range: 1…70 bar | 2800 $ |
| LDW-P-MS-0120 | Sets of weights for this additional piston-/cylinder-units. Range: 1…120 bar | 2800 $ |
| LDW-P-MS-0015-PSI | Sets of weights for this additional piston-/cylinder-units. Range: -15…-0,2 psi (vacuum) | 2300 $ |
| LDW-P-MS-0400-PSI | Sets of weights for this additional piston-/cylinder-units. Range: 3…400 psi | 2300 $ |
| LDW-P-MS-1000-PSI | Sets of weights for this additional piston-/cylinder-units. Range: 15…1000 psi | 3100 $ |
| LDW-P-MS-1600-PSI | Sets of weights for this additional piston-/cylinder-units. Range: 10…1600 psi | 3100 $ |
You can request the necessary certificates, documentation, instructions and user guide for Leitenberger LDW-P using the special form.
You can buy Leitenberger LDW-P in Latvia at a price starting from7400 $ in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email olil@olil.lv. Leitenberger LDW-P price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.
See also: Deadweight testers