Products not found
The Model AQH-20 Indoor Air Quality Meter reduces the number of instruments a contractor has to carry by measuring the carbon dioxide concentration, air temperature, and humidity percentage in one device. A large backlit LCD display shows all three parameters simultaneously. The Model AQH-20 can display dew point or wet bulb temperatures in place of the ambient temperature. Minimum, maximum, and average readings are easily accessible through the function buttons. By pressing the hold key, the current values are held so that they can be recorded. An audible alarm warns the user that the current ambient conditions are becoming hazardous. The Model AQH-20 includes a hard carrying case and batteries.
Retail price from $384,65
- The indoor/outdoor PrimaX I Gas Transmitter detects toxic gases and oxygen
- Worry-free transmission with a 4-20 mA output signal and optional HART digital communication
- Plug-in sensors and easy installation and calibration make this transmitter virtually trouble-free
- Large LCD screen provides information at a glance
price by request
EGD detects combustible gas leaks from: 20ppm Hydrogen 50ppm Methane & Propane
Retail price from $222,69
Industrial Boiler, Heat Pump, A/C & Refrigeration Analyser with KANE LINK
Retail price from $3 145,86
The TracXP TXP-WCR (Wireless Controller Receiver) is available with 900MHz frequency to meet your communication requirements. Each TXP-WCR may be equipped with single or dual gas sensors and transmit two of the 32 maximum channel values to the controller and/or wireless alarm relay.
price by request
The Alarm Notification Assembly is a flexible, cost-effective alarm status annunciator for general-purpose applications. The TXP-ANA offers optional strobe light configurations of one to four strobes, standard 99 dB or optional 120 dB horn, optional configurable Hush/Silence, and optional wireless functionality with the TXP Wireless System.
price by request
CX-6-NO2: Low Voltage (12 to 24 VAC or 12 to 32 VDC) | CX-12-NO2: Line Voltage (100-240 VAC)
The CX-6-NO2 /CX-12-NO2 detects Nitrogen Dioxide (NO2) in commercial facilities such as parking garages, loading docks, etc. It can be used as a stand-alone detector, controller, and as an analog transducer for use with Macurco control panels and other systems
price by request
- Measuring Range 0 – 100% LEL
- Outputs
- Protection Rating Dual IP66 and IP67
- Temperature Range -40°C to 75°C (-40°F to 167°F)
price by request
RGD detects refrigerant gas leaks of: CFC, HFC, HCFC, R11, R22, R134a etc
Retail price from $249,05
Industrial Boiler, Engine & HVACR Analyser with KANE LINK
Retail price from $3 598,26
The TracXP TXP-WAR is a Wireless Relay device that receives a wireless signal from the TXP-WTA Sensor Transmitters to provide electromechanical relays to interface TXP-WTA system alarms with strobes, horns, or other wired components. The TXP-WAR can also be used to serve as a Repeater to extend the wireless communication range to a TXP- controller. These two modes of operation that can be used in individual or simultaneous applications. The TXP-WAR is available with globally acceptable 2.4GHz or 900MHz frequency to meet your communication requirements.
price by request
The Macurco RD-VRF Refrigerant Gas Detector is designed to provide continuous refrigerant monitoring in VRF (Variable Refrigerant Flow) applications as well as other similar applications. The RD-VRF Refrigerant Gas Detector comes standard with 2 alarm levels providing advanced warning via low detection alarming and notification to activate two onboard relays that can be used to control valves to isolate or shutdown refrigerant supply lines, engage exhaust fans, provide notification alarms, and communicate to a Building Management System (BMS). The RD-VRF comes standard with Modbus RS-485 and optional BACnet communication.
price by request
CX-6-CO: Low Voltage (12 to 24 VAC or 12 to 32 VDC)/CX-12-CO: Line Voltage (100-240 VAC)
The CX-6-CO/CX-12-CO detects Carbon Monoxide (CO) in commercial facilities such as parking garages, loading docks, etc. It can be used as a stand-alone detector, controller, and as an analog transducer for use with Macurco control panels and other systems
price by request
- Dual source design provides redundancy and reliable, uninterrupted performance
- Heated optics prevent condensation buildup
- 4–20 mA analog output
- Easy connection using stainless steel junction box
- SIL 2 design provides safety system integration capability
- 316 stainless steel, IP 67-rated, rugged housing protects unit from environmental extremes
price by request
Combustible Gas Leak Detector
Retail price from $116,81
Test boilers with stack draught over 50 mbar with high suction pump
price by request
The TXP-WABX Wireless Alarm Bar is a notification device suitable for Class 1, Division 2 applications. The TXP-WABX communicates directly with TXP-WTA transmitters as well as TXP-WCR and TXP-C16X control panels via 900 MHz radio signal. The onboard horn provides a nominal output of 112 dBA with customizable volume control and has 64 different tones available.
price by request
The RD-24 is a remote input/output device that allows flexibility for applications needing more relays, analog outputs, or analog inputs. Using Modbus communication, you can control multiple I/O based on the application.
price by request
Provides Carbon Monoxide Gas Detection in residential, multi-family. Options available:
- CM-E1: Rectangle Housing
- CM-E1-RF: Round Flush Mount
- CM-E1-RS: Round Surface Mount
price by request
- Indoor/outdoor monitors feature HART, providing more information and features convenient set-up, calibration and diagnostics
- Interchangeable smart sensors eliminate need for reconfiguration
- MSA’s patented SafeSwap sensor design allows sensor replacement without declassifying the hazardous area
- DuraSource Technology extends sensor life
- Automatic calibration adjustments and date stamping
- Stainless steel and polycarbonate models available
price by request
Exhaust Gas Analyser with 6 line display
Retail price from $893,05
The TracXP TXP-T40 transmitter is a highly configurable fixed gas detector supporting single or dual sensor applications in Class 1 Division 1 or Class 1 Division 2 environments. Local and remote sensor options allow the TXP-T40 to adapt to a wide variety of industrial applications.
price by request
Advanced, easy-to-use, multi-gas monitor with built-in pump for confined space entry and worker protection in hazardous environments
price by request


