GEORGIN FKC Differential pressure and Flow transmitter

  • SMART Transmitter 4-20mA + HART protocol
  • Span limits : 0.1 KPa to 20000KPa
  • Rangeability : 100:1
  • Accuracy : 0.065% (0.04% as an option)
  • Power supply 10.5 to 45VDC
  • Process wetted parts material : Inox 316L, Hastelloy, Monel, Tantalum,
  • Process connection : ¼”-18NPT (oval flanges on request)
  • Burnout according NAMUR NE43 recommandations
  • Long term stability : +/- 0.1% of maximum span / 10years

Options: Local analog or digital Indicator, Intrinsically safe version, Explosion proof version, FM, CSA and IECEX certification.
» Stainless Steel electronic housing

			int(7674)
NULL
		

Made in France. brand GEORGIN, model FKC

Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.

price by request

Available

Available

Advantages

Official distributor in Latvia

Time-tested American, European and Asian brands of control and measurent instruments

Advantages

Special price list for organisations

We offer a significant discount for trade organisations and manufacturing companies

Advantages

Worldwide shipping on request

We take care of all logistics and customs clearance. Fast delivery to Baltic countries

Advantages

After-sales service and support

Warranty service and repair, expert assistance in the operation of the instruments

Description of GEORGIN FKC

The ProcessX differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and transmits a proportional 4 to 20 mA signal.
The transmitter utilizes a unique micro machined capacitance silicon sensor with state-of-the-art microprocessor
technology to provide exceptional performance and functionality.

FEATURES

High accuracy up to ±0.04%:
0.065% accuracy as standard. Georgin’s micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjustment. 0.04% accuracy as option.

Minimum inventory and design:
Electronics unit, local indicators and electronics housing are interchageable among all ProcessX transmitters.

Minimum environmental influence:
The “Advanced Floating Cell” design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual field applications.

Georgin/HART bilingual communications protocol:
ProcessX series transmitter offers bilingual communications to speak both Georgin proprietary protocol and HART. Any HART compatible devices can communicate with ProcessX.

Application flexibility:
Various options that render the ProcessX suitable for almost any process applications include :

  • Analog indicator at either the electronics side or terminal side,
  • Full range of hazardous area approvals,
  • Built-in RFI filter and lightning arrester,
  • 5 digit LCD meter with engineering unit,
  • Stainless steel electronics housing,
  • Wide selection of materials.

Programmable output Linearization Function:
Output signal can be freely programmable. (Up to 14 compensated points at approximation).

Burnout current flexibility (Under Scale: 3.2 to 4.0 mA, Over Scale: 20.0 to 22.5 mA):
Burnout signal level is adjustable using Model FXW or Hand Held Communicator (HHC) to comply with NAMUR NE43.

Dry calibration without reference pressure:
Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration.

Technical specifications of GEORGIN FKC

  • Type : FKC : Smart, 4-20 mA DC + Georgin/Hart digital signal
  • Service : Liquid, gas, or vapour
  • Remark : To minimize environmental influence, span should be greater than 1/40 of the max. span in most applications.
  • *Important : For FKC#49, max possible overload pressure on LP side must be ≤ 100 bar. The accuracy is not guaranteed when used at negative DP.
  • Lower limit of static pressure (vacuum limit) : Silicone fill sensor : See Fig. 1.  Fluorinated fill sensor : 66 kPa abs (500 mmHg abs) at temperature below 60°C
  • Over range limit : To maximum static pressure limit.
  • Output signal : 4 to 20 mA DC (linear or square root) with digital signal superimposed on the analogic signal.
  • Power supply : Transmitter operates on 10.5 V to 45 V DC at transmitter terminals. 10.5 V to 32 V DC for the units with optional arrester.

 

Type Static pressure MPa {bar} Span limit kPa {mbar} Range limit kPa {mbar}
Min. Max.
FKC 11  -0.1 to +3.2 {-1 to +32} 0,1 {1} 1 {10}  ±1 {±10}
FKC 22  -0.1 to +10 {-1 to +100} 0,1 {1} 6 {60}  ±6 {±60}
FKC 33  -0.1 to +16 {-1 to +160} 0,32 {3,2} 32 {320}  ±32 {±320}
FKC 35  -0.1 to +16 {-1 to +160} 1,3 {13} 130 {1300}  ±130 {±1300}
FKC 36  -0.1 to +16 {-1 to +160} 30 {300} 3000 {30000}  ±3000 {±30000}
FKC 38  -0.1 to +16 {-1 to +160} 30 {300} 3000 {30000} ±3000 {±30000}
FKC 43  -0.1 to +42 {-1 to +420} 0,32 {3,2} 32 {320}  ±32 {±320}
FKC 45  -0.1 to +42 {-1 to +420} 1,3 {13} 130 {1300}  ±130 {±1300}
FKC 46  -0.1 to +42 {-1 to +420} 5 {50} 500 {5000}  ±500 {±5000}
FKC 48  -0.1 to +30 {-1 to +300} 30 {300} 3000 {30000}  ±3000 {±30000}
FKC 49+  -0.1 to +30 {-1 to +300} 500 {5000} 20000 {200000}  +20000,-10000 {+200000,-100000}
Load More Items

User Guide and Instruction manual for GEORGIN FKC

You can request the necessary certificates, documentation, instructions and user guide for GEORGIN FKC using the special form.

You can buy GEORGIN FKC in Latvia at a favourable price in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email . GEORGIN FKC price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.