TSI 9600/9630/9650 VelociCalc and VelociCalc Pro Ventilation Meters

The VelociCalc 9600 Series Multi-Function Ventilation Meters use guided workflows programmed for professionals allowing you to customize the instrument performance to meet your needs with the touch of one button.

			int(17644)
NULL
		

Made in USA. brand TSI, model 9600/9630/9650

Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.

price by request

Available

Available

Advantages

Official distributor in Latvia

Time-tested American, European and Asian brands of control and measurent instruments

Advantages

Special price list for organisations

We offer a significant discount for trade organisations and manufacturing companies

Advantages

Worldwide shipping on request

We take care of all logistics and customs clearance. Fast delivery to Baltic countries

Advantages

After-sales service and support

Warranty service and repair, expert assistance in the operation of the instruments

Descriptions of TSI 9600/9630/9650

The high-resolution color screen displays multiple measurements simultaneously in real-time with on-screen prompts to guide you through instrument setup and operation.
The VelociCalc Multi-Function Ventilation Meter 9600 series includes a built-in workflow for calculating the percentage of outside air used to determine ventilation effectiveness in a building or room. The VelociCalc Pro adds built-in workflows for heat flow calculation and four methodologies for performing a duct traverse.
It’s ergonomic design includes a probe holder and integrated magnets allowing for attachment to exposed ductwork, chemical fume hoods and biological safety cabinet frames for hands-free operation. These instruments are available with or without a differential pressure sensor, and are designed to work with a wide range of plug-in probes.

Applications
▪ HVAC testing and balancing
▪ Cleanroom testing
▪ Biological safety cabinet and laboratory fume hood testing
▪ HVAC commissioning and troubleshooting
▪ IAQ investigations
▪ Ventilation effectiveness with percent outside air calculation

Features and Benefits
▪ Large, high-resolution color display
▪ Intuitive menu structure allows for ease of use and setup
▪ Optional smart plug-in probes, including thermoanemometer, rotating vane and CO2 probes with calibration certificates
▪ User-customizable soft keys for quick access to common functions
▪ Integrated magnets for hands-free operation
▪ Programmable for local language
▪ Air density compensation with on board barometric pressure sensor and temperature input

Additional Features for Model 9630 and 9650
▪ Static and differential pressure measurement
▪ Pitot probe duct traverse
▪ Programmable K-factors

Technical specifications of TSI 9600/9630/9650

  1.  Pressure velocity measurements are not recommended below 1,000 ft/min (5 m/s) and are best suited to velocities over 2,000 ft/min
    (10.00 m/s). Range can vary depending on barometric pressure.
  2. Accuracy is a function of converting pressure to velocity. Conversion accuracy improves when actual pressure values increase.
  3. Overpressure range = 190 in. H2O, 48 kPa (360 mmHg).
  4. Temperature compensated over an air temperature range of 40 to 150 °F (5 to 65 °C).
  5. The accuracy statement begins at 30 ft/min through 9,999 ft/min (0.15 m/s through 50 m/s).
  6. Accuracy with instrument case at 77 °F (25 °C), add uncertainty of 0.05 °F/°F (0.03 °C/°C) for change in instrument temperature.
  7. Accuracy with probe at 77 °F (25 °C). Add uncertainty of 0.1% RH/ °F (0.2% RH/ °C) for change in probe temperature. Includes 1%hysteresis.
  8. At calibration temperature. Add uncertainty of ±0.28%/ °F (0.5%/ °C) for change in temperature.
  9. At 77 °F (25 °C). Add uncertainty of ±0.2%/ °F (0.36%/ °C) for change in temperature.
Parameter/Function 9600 9630 9650-NB 9650
Barometric Pressure
Differential Pressure
Thermocouple
Thermoanemometer Probes  (960, 962, 964, 966)
IAQ Probes (980, 982)
Pitot Probe
Air Density Correction
Calculate Flow
K-factor Flow
% Outside Air Calculation
ASHRAE 111 Log-Tchebycheff  Duct Traverse Workflow
ASHRAE 111 Equal Area  Duct Traverse Workflow
EN 16211 Duct  Traverse Workflow
EN 12599 duct  Traverse Workflow
Heat Flow Calculation  (BTU/h, kW)
Wired USB Printer
Bluetooth Printer
Load More Items

□ = Optional
Note: Displayed workflows are dependent on instrument model and attached probe.

 

User Guide and Instruction manual for TSI 9600/9630/9650

You can request the necessary certificates, documentation, instructions and user guide for TSI 9600/9630/9650 using the special form.

You can buy TSI 9600/9630/9650 in Latvia at a favourable price in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email . TSI 9600/9630/9650 price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.