+371 672 70580

Mon-Fri: 9:00 - 17:00 LV

Email:

TSI 7515/7525/7545 IAQ-CALC INDOOR AIR QUALITY METERS

TSI IAQ-Calc Meters are outstanding instruments for investigating and monitoring indoor air quality (IAQ).

 

			int(17786)
NULL
		

Made in USA. brand TSI, model 7515/7525/7545

Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.

price by request

Available

Available

Advantages

Official distributor in Latvia

Time-tested American, European and Asian brands of control and measurent instruments

Advantages

Special price list for organisations

We offer a significant discount for trade organisations and manufacturing companies

Advantages

Worldwide shipping on request

We take care of all logistics and customs clearance. Fast delivery to Baltic countries

Advantages

After-sales service and support

Warranty service and repair, expert assistance in the operation of the instruments

Descriptions of TSI 7515/7525/7545

  • Model 7515 is a cost-effective meter for carbon dioxide (CO2) measurements.
  • Models 7525 and 7545 simultaneously measure and data log multiple parameters.
  • Model 7525 measures CO2, temperature, humidity, and calculates dew point, wet bulb temperature, and percentage outside air.
  • Model 7545 adds detection of carbon monoxide (CO).

Applications

+ Conduct IAQ evaluations

+ Verify building HVAC system performance

+ Examine building IAQ conditions to optimize worker productivity

+ Comply with regulations and guidelines

Features and Benefits – All Models

+ Low-drift NDIR CO2 sensor for stable, accurate readings

+ Sampling function records multiple point measurements

+ Ergonomic, overmolded case design

Models 7525 and 7545

+ Temperature and relative humidity measurements help determine thermal comfort

+ Calculates percentage outside air from either CO2 or temperature

+ Directly calculates dew point and wet bulb temperatures

+ Electrochemical sensor measures CO (Model 7545)

+ Displays up to three parameters

+ TSI LogDat2™ software permits easy transfer of data to a computer

+ Data can be reviewed on-screen, or downloaded to a computer for easy report generation

+ Statistics function displays average, maximum and minimum values, and the number of recorded samples

Technical specifications of TSI 7515/7525/7545

  • CO2

Sensor Type – Dual-wavelength NDIR  (non-dispersive infrared)

Range – 0 to 5,000 ppm

Accuracy – ±3.0% of reading or ±50 ppm, whichever is greater

Resolution – 1 ppm

Response Time – 20 seconds

  • Temperature (Models 7525 and 7545)

Sensor Type – Thermistor

Range  – 0 to 60°C (32 to 140°F)

Accuracy   – ±0.5°C (±1.0°F)

Resolution – 0.1°C (0.1°F)

Response Time – 30 seconds (90% of final value, air velocity at 2 m/s [400 ft/min])

  • Relative Humidity (Models 7525 and 7545)

Sensor Type –  Thin-film capacitive

Range – 5% to 95% RH

Accuracy – ±3.0% RH

Resolution – 0.1% RH

Response Time – 20 seconds (for 63% of final value)

  • Percentage Outside Air (Models 7525 and 7545)

Range – 0 to 100%

Resolution – 0.1%

  • CO (Model 7545 only)

Sensor Type – Electro-chemical

Range – 0 to 500 ppm

Accuracy – ±3.0% of reading or ±3 ppm, whichever is greater

Resolution – 0.1 ppm

Response Time – <60 seconds to 90% step change

  • Operating Temperature –5 to 45°C (40 to 113°F)
  • Storage Temperature – -20 to 60°C (-4 to 140°F )
  • Logging Capability (Models 7525 and 7545)

Ranges   – Model 7525 logs up to 30,300 data points with key (3) measured parameters enabled Model 7545 logs up to 26,900 data points with key (4) measured parameters enabled

Time Constant  –  1 sec, 5 sec, 10 sec, 20 sec, 30 sec (user selectable)

Log Intervals – 1 second up to 1 hour (user selectable)

  • Meter Dimensions (all models) –8.4 cm x 17.8 cm x 4.4 cm (3.3 in. x 7.0 in. x 1.8 in.)
  • Probe Dimensions (Model 7515)

Length  – 7.0 cm (2.75 in.)

Diameter – 1.9 cm (0.75 in. )

  • Probe Dimensions (Models 7525 and 7545)

Length – 17.8 cm (7.0 in. )

Diameter – 1.9 cm (0.75 in. )

  • Weight (with batteries) –0.27 kg (0.6 lbs)
  • Power Requirements

Model 7515 –  Four AA-size batteries

Models 7525 and 7545 – Four AA-size batteries or AC adapter

 

7515 7525 7545
CO2 + + +
CO +
Temperature + +
Humidity + +
Percentage outside air + +
Dew point + +
Wet bulb temperature + +
Data logging/downloading + +
Statistics + + +
Review data + +
Certificate of Calibration + + +

 

User Guide and Instruction manual for TSI 7515/7525/7545

You can request the necessary certificates, documentation, instructions and user guide for TSI 7515/7525/7545 using the special form.

You can buy TSI 7515/7525/7545 in Latvia at a favourable price in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email . TSI 7515/7525/7545 price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.