+371 672 70580

Mon-Fri: 9:00 - 17:00 LV

Email:

TSI 3321 Aerodynamic Particle Sizer APS

High-resolution aerodynamic sizing plus light-scattering intensity

			int(15591)
NULL
		

Made in USA. brand TSI, model 3321

Fast delivery to Latvia, Estonia and Lithuania. International delivery to Europe, Asia, Africa and other continents available on request
Our warehouse is located in Riga, Latvia.

price by request

Available

Available

Advantages

Official distributor in Latvia

Time-tested American, European and Asian brands of control and measurent instruments

Advantages

Special price list for organisations

We offer a significant discount for trade organisations and manufacturing companies

Advantages

Worldwide shipping on request

We take care of all logistics and customs clearance. Fast delivery to Baltic countries

Advantages

After-sales service and support

Warranty service and repair, expert assistance in the operation of the instruments

Description of TSI 3321

The Aerodynamic Particle Sizer® (APS™) 3321 spectrometer provides high resolution, real-time aerodynamic measurements of particles from 0.5 to 20 μm. This unique particle sizer also measures lightscattering intensity in the equivalent optical size range of 0.37 to 20 μm. By providing paired data for each particle, the APS™ spectrometer opens up exciting new possibilities for those interested in studying the makeup of an aerosol.

The APS™ spectrometer uses a patented*, doublecrest optical system for unmatched sizing accuracy. It also includes a redesigned nozzle configuration and improved signal processing. The result is greater small-particle sizing efficiency, improved accuracy of mass-weighted distributions, and virtual elimination of false background counts.

Features and Benefits

  • Double-crest optics produce high-quality measurements
  • Measures aerodynamic particle size from 0.5 to 20 μm
  • Measures light-scattering intensity from 0.37 to 20 μm
  • Real-time aerodynamic sizing
  • No need to wait for cascade impactor measurements
  • High size resolution – 52 size channels
  • Independent of optical properties of the particles and fluid

Applications

  • Inhalation toxicology
  • Drug delivery studies
  • Atmospheric studies
  • Ambient air monitoring
  • Indoor air quality monitoring
  • Filter and air cleaner testing
  • Biohazard detection
  • Test aerosols characterization
  • Usable for particle instrument calibration
  • Spray technology
  • Performance evaluations of aerodynamic devices
  • Powder sizing
  • Basic research

Technical specifications of TSI 3321

Measurement Technique Time-of-flight of individual particles measured in an accelerating flow field with a single, high-speed timing processor; coincidence detection achieved using a patented, double-crest optical system; particle size binning based on internally stored calibration curve
Particle Size Range 0.5 to 20 μm aerodynamic sizing, 0.37 to 20 μm optical detection (PSL equivalent)
Aerodynamic Size Resolution 0.02 μm at 1.0 μm, 0.03 μm at 10 μm
Light Scattering (log-compressed) 16 channels of light-scattering intensity (displayed); 64 channels of raw light-scattering data
Particle Type Airborne solids and nonvolatile liquids
Maximum Recommended Particle Concentration 1,000 particles/cm3 at 0.5 μm with < 5% coincidence; 1,000 particles/ cm3 at 10.0 μm with < 10% coincidence; usable data up to 10,000 particles/cm3
Minimum Particle Concentration 0.001 particle/cm3
Concentration Accuracy ±10% of reading plus variation from counting statistics
Maximum Processing Rate for Aerodynamic Sizing >200,000 particles/sec
Sampling Time** Programmable and repeatable from 1 sec to 18 hr per sample; sampling schedules selected by user
Atmospheric Pressure Correction Automatic correction between 400 and 1,030 mbar (full correction between 700 and 1,030 mbar)
Laser Source 30-mW, 655-nm laser diode
Detector Avalanche photodetector (APD)
Front-panel Display 320 x 240 pixels
Operating Temperature 10 to 40°C (50 to 104°F)
Operating Humidity 10 to 90% R.H., non-condensing
Power 100 to 240 VAC, 50/60 Hz, 100 W, single phase or 24 VDC
Computer Requirements Pentium® 4 processor with 2-GHz speed or better, at least 512 MB RAM
Operating System Windows® 7 operating system or better
Communications DSUB 9-pin RS-232
Display Resolution
Particle Size 32 channels per decade of particle size (logarithmic), 52 channels total; 1,024 bins of raw time-of-flight data (4 nsec per bin) in uncorrelated mode
Flow Rates*
Aerosol Sample 1.0 L/min ±0.1
Sheath Air 4.0 L/min ±0.1
Total 5.0 L/min ±0.2
Outputs
Digital I/O 15-pin port (3 inputs, 3 outputs) for external device control and two analog inputs (0 to 10 V)
Configurable Analog BNC (0 to 10 V)
Analog Pulse BNC
Digital Time-of-flight BNC
Dimensions
Aerosol Inlet 3/4 in. (O.D.)
Sensor (HWD) 18 cm x 30 cm x 38 cm (7 in. x 12 in. x 15 in.)
Weight 10 kg (22 lb.)

User Guide and Instruction manual for TSI 3321

You can request the necessary certificates, documentation, instructions and user guide for TSI 3321 using the special form.

You can buy TSI 3321 in Latvia at a favourable price in «OLIL SIA» by leaving a request on the website, by phone +371 672 70580 or by email . TSI 3321 price are subject to change depending on exchange rates. We deliver instruments by transport companies in Latvia, Estonia and Lithuania. Worldwide shipping to Europe, Asia, Africa, North and South America available on request.